Comparison of a bolt-connected external ventricular drain with a tunneled external ventricular drain - a narrative review and meta-analysis

期刊

NEUROSURGICAL REVIEW
卷 45, 期 2, 页码 937-949

出版社

SPRINGER
DOI: 10.1007/s10143-021-01639-6

关键词

External ventricular drain; Bolt-connected; Tunneled; CSF infection; Multiple punctures

向作者/读者索取更多资源

The bolt-connected EVD showed significantly better chances of optimal placement, lower risk of CSF infection, and reduced accidental disconnection compared to traditional tunneled EVD. However, there was no significant difference between the two techniques in terms of complications like multiple punctures, iatrogenic intracranial hemorrhage, and need for reoperation. Further prospective studies are needed to confirm these findings due to the retrospective nature of the included studies.
External ventricular drain (EVD) is one of the most commonly performed neurosurgical procedures. EVD can be associated with high rates of complications like misplacement, iatrogenic hemorrhage, and CSF infection. Several modifications have been proposed in the EVD insertion techniques to decrease the risk of these complications. Bolt-connected EVD, one of these modifications which involves insertion of a bolt in the burr hole, has been proposed to have better chances of optimal placement of EVD tip, lesser risk of CSF infection, and accidental pullout. A comprehensive search of different databases was performed to retrieve studies comparing the bolt-connected EVD with tunneled EVD and meta-analysis was done. Seven studies met inclusion criteria and were included in the meta- analysis. Our analysis revealed that bolt-connected EVD is associated with significantly better chances of optimal placement than traditional tunneled EVD (MH OR-1.65, 95% CI 1.14 to 2.40, p = 0.008). We also observed that bolt-connected EVD is associated with significantly decreased risk of CSF infection (MH OR-0.60, 95% CI 0.39 to 0.94, p = 0.026), EVD malfunction (MH OR-0.31, 95% CI 0.16 to 0.58, p = 0.0003), and accidental disconnection (MH OR-0.09, 95% CI 0.03 to 0.26, p < 0.0001) as compared to traditional tunneled EVD. The difference between the two techniques was not statistically significant for complications, multiple punctures done for insertion of EVD, iatrogenic intracranial, and need of reoperation. Bolt-connected external ventricular drain is associated with significantly more chances of optimal placement and lesser chances of accidental discontinuation and CSF infection than tunneled EVD. There was no statistically significant difference noted between the two techniques for multiple punctures done for insertion of EVD, iatrogenic intracranial hemorrhage and need of reoperation. However, most of the included studies were retrospective. Thus, the results from the meta-analysis should be interpreted with caution as further prospective high-quality studies are needed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据