4.4 Article

Absorbance-based detection of arsenic in a microfluidic system with push-and-pull pumping

期刊

MICROELECTRONIC ENGINEERING
卷 247, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.mee.2021.111583

关键词

Microfluidic chip; Arsenic detection; Push-and-pull pumping; Gold nanoparticles

资金

  1. Scientific and Technological Research Council of Turkey [217S518]
  2. Turkish Academy of Science
  3. Turkish Council of Higher Education

向作者/读者索取更多资源

This study focused on developing a microfluidic platform for sensitive detection of arsenic using a push-and-pull pumping method. The method enables detection of arsenic down to 2.2 µg/L concentration levels in drinking water, which is well below the allowed maximum concentration of 10 µg/L by WHO. Multiple push-and-pull pumping of fixed volume of sample and AuNPs with a syringe pump can improve binding efficiency in the microfluidic channel.
Rapid and portable analysis of arsenic (As) contamination in drinking water is very important due to its adverse health effects on humans. Available commercial detection kits have shown low sensitivity and selectivity in analysis, and also they can generate harmful by-products. Microfluidic-based approaches allow portable analysis with gold nanoparticles (AuNPs) as labels. However, they need complex surface modification steps that complicate detection protocols. Due to the lack of precise sensing and affordable solution, we focused on developing a microfluidic platform that uses a push-and-pull pumping method for sensitive detection of As. In this detection principle, a sample is introduced in the microfluidic channel modified with -SH functional groups where As can bind. Then, AuNPs are given in the channel and AuNPs bind on free -SH functional groups which are not allocated with As. Absorbance measurements are conducted to detect AuNPs absorbed on the surfaces and the resulting absorbance value is inversely proportional with As concentration. The method enables detection of As down to 2.2 mu g/L concentration levels in drinking water, which is well-below the allowed maximum As concentration of 10 mu g/L in the drinking waters by the World Health Organization (WHO). The paper reveals that multiple push-and-pull pumping of fixed volume of sample and AuNPs with a syringe pump can improve the binding efficiency in the microfluidic channel. With this technique, low amounts of sample (1 mL) and short total assay time (25 min) are sufficient to detect As.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据