4.7 Article

Fabrication of highly sensitive anticancer drug sensor based on heterostructured ZnO-Co3O4 capped on carbon nitride nanomaterials

期刊

MICROCHEMICAL JOURNAL
卷 167, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2021.106244

关键词

Nano-heterostructure ZIF MOFs; ZnO-Co3O4 MOFs; Anti-cancer drug; Electrochemical sensor; Flutamide

资金

  1. Ministry of Science and Technology [MOST1082221E027063]
  2. King Saud University, Riyadh, Saudi Arabia [RSP-2020/265]

向作者/读者索取更多资源

The zinc oxide-cobalt oxide capped on carbon nitride nanocomposite prepared via hydrothermal assisted sonochemical synthesis is effective in detecting the anti-cancer drug flutamide, showing good sensitivity and detection performance. It is suitable for analyzing biological samples such as urine and blood serum.
Flutamide (FLT) is a nonsteroidal and antiandrogen drug with an explicit anti-androgenic behavior. Due to this reason, they are employed to treat prostate cancer. Also, they are utilized to cure superfluous androgen echelons. In recent days, zeolitic-imidazolate frameworks (ZIF) based metal-organic frameworks (MOFs) have grasped more consideration in the synthesis and preparation of MOFs based nanocomposite. Similarly, electrochemical detection of anti-cancer drugs are much needed. Herein, we report a novel preparation of zinc oxide-cobalt oxide capped on carbon nitride nanocomposite using a hydrothermal assisted sonochemical synthesis for detecting anti-cancer drug flutamide (FLT). The as-prepared ZnO-Co3O4@C3N4 NC was physically characterized using Xray diffraction, X-ray photoelectron spectroscopy, scanning electron microscope, and transmission electron microscope. Then, an as-prepared sample was electrochemically analyzed to detect anti-cancer drug FLT. Electrochemical impedance spectroscopy (EIS) was studied, and the ZnO-Co3O4@C3N4 NC modified electrode has displayed a lower Rct value. ZnO-Co3O4@C3N4 NC modified electrode shows a respectable linear range (0.01-98.6 mu M) with a low detection limit (0.00373 mu M) and good sensitivity (5.331 mu A.mu M-1.cm(-2)) towards FLT detection by differential pulse voltammetry (DPV) technique. Similarly, the ZnO-Co3O4@C3N4 NC sensor exhibits good selectivity, repeatability, and reproducibility towards FLT. Also, for real sample analysis, biological samples like urine and blood serum were investigated, and the results show reasonable practicability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据