- Research on Measurement Standards for Redefinition of SI Units - Korea Research Institute of Standards and Science [KRISS-2021-GP2021-0001]
This study reports a 14-month measurement of the absolute frequency of the S-1(0)-P-3(0) transition in the Yb-171 optical lattice clock at KRISS, with high accuracy and good agreement with other reports. The determined absolute frequency is expected to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.
We report a measurement of the absolute frequency of the S-1(0)-P-3(0) transition in the Yb-171 optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via International Atomic Time. The determined absolute frequency is 518 295 836 590 863.75(14) Hz with the relative frequency uncertainty of 2.6 x 10(-16), which agrees well with other reports. This result is expected to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.