4.5 Article

Patient with sick sinus syndrome and implanted dual-chamber pacemaker with reduced P-wave duration following low interatrial septal pacing Case report

期刊

MEDICINE
卷 100, 期 35, 页码 -

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MD.0000000000027076

关键词

coronary sinus; interatrial septum; pacing; sick sinus syndrome

向作者/读者索取更多资源

The study focused on a 74-year-old female patient with sick sinus syndrome (SSS) who had a previously implanted physiological DDD/R pacemaker. The pacing system located in the low interatrial septal region reduced P-wave duration but did not prevent the development of atrial arrhythmias.
Introduction: A dual-chamber pacemaker (DDD/R) for a sinus node disease is sometimes referred to as a physiological pacemaker as it maintains atrioventricular synchrony, however several clinical trials have proved its inferiority to a nonphysiological single-chamber ventricular back-up pacing. Patient concerns: A subject of the study is a 74-year-old woman with a sick sinus syndrome (SSS) and a previously implanted physiological DDD/R pacemaker. The SSS was diagnosed because of patient's very slow sinus rhythm of about 36 bpm, and due to several episodes of dizziness. After the DDD/R implantation the percentage of atrial pacing approached 100%, with almost none ventricular pacing. Diagnoses: Sick sinus syndrome, complete Bachmann's bundle block, atrial fibrillation, atrial flutter. Interventions: The patient was previously implanted with a physiological DDD/R pacemaker. Several years after the implantation, the atrial fibrillation was diagnosed and the pulmonary vein isolation was then performed by cryoablation. During the follow-up after pulmonary vein isolation, the improvement of mitral filling parameters was assessed using echocardiography. Shortly thereafter the patient developed the persistent paroxysm of a typical atrial flutter which was successfully terminated using a radiofrequency ablation. No recurrence thereof has been observed ever since (24 months). Outcomes: The atrial electrode of the pacing system was implanted within the low interatrial septal region that resulted in a reduced P-wave duration compared to native sinus rhythm P-waves. The said morphology was deformed because of the complete Bachmann bundle block. That approach, despite a nonphysiological direction of an atrial activation, yielded relatively short P-waves (paced P-wave: 179 ms vs intrinsic sinus P-wave: 237 ms). It also contributed to a significantly shorter PR interval (paced PR: 204 ms vs sinus rhythm PR: 254 ms). Conclusions: The authors took into consideration different aspects of alternative right atrial pacing sites. This report has shown that in some patients with a sinus node disease, low interatrial septal pacing can reduce the P-wave duration but does not prevent from the development of atrial arrhythmias.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据