4.6 Article

Diffeomorphic respiratory motion estimation of thoracoabdominal organs for image-guided interventions

期刊

MEDICAL PHYSICS
卷 48, 期 8, 页码 4160-4176

出版社

WILEY
DOI: 10.1002/mp.15008

关键词

diffeomorphic deformation field; needle insertion; percutaneous image-guided interventions; respiratory motion estimation; respiratory motion variation

资金

  1. National Natural Science Foundation of China [12026604, 61803362, U1813204]
  2. Key Fundamental Research Program of Shenzhen [JCYJ20200109115201707, JCYJ20180507182415428, KQTD2016113010571019]
  3. Shenzhen Institute of Artificial Intelligence and Robotics for Society
  4. CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology

向作者/读者索取更多资源

A data-driven patient-specific hierarchical respiratory motion estimation framework is proposed for accurately estimating the position of tumors and surrounding vital tissues in real-time during percutaneous image-guided interventions. Experimental results demonstrate the efficacy of the method in improving accuracy and clinical relevance in both animal and human subjects.
Purpose Percutaneous image-guided interventions are commonly used for the diagnosis and treatment of cancer. In practice, physiological breathing-induced motion increases the difficulty of accurately inserting needles into tumors without impairing the surrounding vital structures. In this work, we propose a data-driven patient-specific hierarchical respiratory motion estimation framework to accurately estimate the position of a tumor and surrounding vital tissues in real time. Methods The motion of optical markers attached to the chest or abdomen skin is used as a surrogate signal to estimate tumor motion based on epsilon-support vector regression (epsilon-SVR). With the estimated tumor motion as the input, a novel respiratory motion model is developed to estimate the diffeomorphic deformation field of the whole organ (liver or lung) without intraoperative, iterative optimization computations. The respiratory motion model of the whole organ is established in Lie algebra space based on the kriging algorithm to ensure that the estimated deformation field is diffeomorphic, optimal, and unbiased. Preoperative prior knowledge for modeling the motion of whole organs is obtained by deformation registration between four-dimensional computed tomography (4D CT) images using a hybrid diffeomorphic registration method. Results and Conclusions Experimental results on an in vivo beagle dog show that the minimum value of the determinant of the Jacobian of the estimated deformation field is greater than zero, so the estimated deformation field of the whole liver with our method is diffeomorphic. The mean position error of the tumor is 1.2 mm corresponding to a mean accuracy improvement of 76.5%, and the mean position error of the whole liver is 2.1 mm, corresponding to a mean accuracy improvement of 37.9%. The experimental results based on public human subject data show that the mean position error of the tumor is 1.1 mm, corresponding to a mean accuracy improvement of 83.1%, and the mean position error of the whole lung is 2.1 mm, corresponding to a mean accuracy improvement of 41.4%. The positioning errors for the tumor and whole organ are hierarchical and consistent with clinical demand.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据