期刊
MEDICAL PHYSICS
卷 48, 期 7, 页码 3842-3851出版社
WILEY
DOI: 10.1002/mp.14991
关键词
Tc-99m-macroaggregated albumin; attenuation correction; respiratory motion; segmentation; SPECT; CT
资金
- Science and Technology Development Fund (FDCT) of Macau [0091/2019/A2]
- National Natural Science Foundation of China (NSFC) [81922080]
This study aims to evaluate the effects of AC and VOI segmentation on the quantitation accuracy of SPECT, and proposes a CT map for the estimation of LSF and TNR. The results show that HCT-MID performs slightly better for AC effect and HCT-EX and HCT-MID perform better for VOI effect in LSF and TNR estimation.
Purpose Conventional Tc-99m-macroaggregated albumin (Tc-99m-MAA) planar scintigraphy overestimates lung shunt fraction (LSF) compared to SPECT/CT. However, the respiratory motion artifact due to the temporal mismatch between static SPECT and helical CT (HCT) may compromise the SPECT quantitation accuracy by incorrect attenuation correction (AC) and volume-of-interest (VOI) segmentation. This study aims to evaluate AC and VOI segmentation effects systematically and to propose a CT map for LSF and tumor-to-normal liver ratio (TNR) estimation in static Tc-99m-MAA SPECT/CT. Methods The 4D XCAT phantom was used to simulate a phantom population of 120 phantoms, modeling 10 different anatomical variations, nine TNRs (2-13.2), nine tumor sizes (2-6.7 cm diameter), eight tumor locations, three axial motion amplitudes of 1, 1.5, and 2 (cm), and four LSFs of 5%, 10%, 15%, and 20%. An analytical projector for low-energy high-resolution parallel-hole collimator was used to simulate 60 noisy projections over 360 degrees, modeling attenuation and geometric collimator-detector response (GCDR). AC and VOI mismatch effects were investigated independently and together, using cine average CT (CACT), HCT at end-inspiration (HCT-IN), mid-respiration (HCT-MID), and end-expiration (HCT-EX) respectively as attenuation and segmentation maps. SPECT images without motion, AC, and VOI errors were also generated as reference. LSF and TNR errors were measured as compared to the ground truth. Results HCT-MID has slightly better performance for AC effect compared with other CT maps in LSF and TNR estimation, while HCT-EX and HCT-MID perform better for VOI effect. For a respiratory motion amplitude of 1.5 cm and a LSF of 5%, the LSF errors are 19.56 +/- 4.58%, -6.79 +/- 1.74%, 77.29 +/- 14.74%, and 111.25 +/- 18.29% corresponding to HCT-MID, HCT-EX, HCT-IN, and CACT in static SPECT. The TNR errors are -12.38 +/- 6.42%, -20.55 +/- 11.25%, -20.89 +/- 9.98%, and -22.89 +/- 14.38% respectively. HCT-MID has the best performance for LSF estimation for LSF > 10% and TNR estimation, followed by HCT-EX, HCT-IN, and CACT. Conclusions The HCT-MID is recommended for AC and segmentation to alleviate respiratory artifacts and improve quantitation accuracy in Y-90 radioembolization treatment planning. HCT-EX would also be a recommended choice if HCT-MID is not available.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据