4.5 Article

Changes of biomechanics induced by Equistasi® in Parkinson's disease: coupling between balance and lower limb joints kinematics

期刊

MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING
卷 59, 期 7-8, 页码 1403-1415

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s11517-021-02373-3

关键词

Parkinson's disease; Gait analysis; Neurorehabilitation; Clinical biomechanics

资金

  1. Fondazione Fresco Parkinson Institute Italia Onlus
  2. MIUR (Italian Minister for Education) under the initiative Departments of Excellence [232/2016]

向作者/读者索取更多资源

This study investigated the effects of Equistasi device on gait and balance in patients with Parkinson's disease. Significant improvements were observed in trunk flexion extension and in ankle dorsi-plantarflexion after treatment with the active device, as well as in balance assessment corresponding to vestibular system frequencies. These findings suggest potential new rehabilitative interventions for Parkinson's disease.
Axial disorders, including postural deformities, postural instability, and gait disturbances, are among the most disabling symptoms of Parkinson's disease (PD). Equistasi (R), a wearable proprioceptive stabilizer device, has been proposed as neurological rehabilitative device for this set of symptoms. To investigate the effects of the device on gait and balance, 24 participants affected by PD were enrolled in this crossover double-dummy, randomized, controlled study. Subjects were assessed four times before and after 8 weeks treatment with either active or placebo device; one-month wash-out was taken between treatments, in a 20-week timeframe. Gait analysis and instrumented Romberg test were performed with the aid of a sterofotogrammetric system and two force plates. Joint kinematics, spatiotemporal parameters of gait and center of pressure parameters were extracted. Paired T-test (p < 0.05) was adopted after evidence of normality to compare the variables across different acquisition sessions; Wilcoxon was adopted for non-normal distributions. Before and after the treatment with the active device, statistically significant improvements were observed in trunk flexion extension and in the ankle dorsi-plantarflexion. Regarding balance assessment, significant improvements were reported at the frequencies corresponding to vestibular system. These findings may open new possibilities on PD's rehabilitative interventions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。