4.5 Article

Multiecho complex total field inversion method (mcTFI) for improved signal modeling in quantitative susceptibility mapping

期刊

MAGNETIC RESONANCE IN MEDICINE
卷 -, 期 -, 页码 -

出版社

WILEY
DOI: 10.1002/mrm.28814

关键词

brain imaging; nonlinear total field inversion; quantitative susceptibility mapping

资金

  1. Foundation for the National Institutes of Health [R01CA181566, R01NS090464, R01NS095562, R21EB024366, S10OD021782]

向作者/读者索取更多资源

The proposed multiecho complex total field inversion (mcTFI) method improved QSM reconstruction accuracy over traditional field-to-source inversion through better signal modeling. It demonstrated more accurate QSM reconstruction in numerical brain simulations with lesions, as well as better image quality with fewer artifacts in brains with intracerebral hemorrhage scanned at 3T and healthy brains scanned at 7T.
Purpose Typical quantitative susceptibility mapping (QSM) reconstruction steps consist of first estimating the magnetization field from the gradient-echo images, and then reconstructing the susceptibility map from the estimated field. The errors from the field-estimation steps may propagate into the final QSM map, and the noise in the estimated field map may no longer be zero-mean Gaussian noise, thus, causing streaking artifacts in the resulting QSM. A multiecho complex total field inversion (mcTFI) method was developed to compute the susceptibility map directly from the multiecho gradient echo images using an improved signal model that retains the Gaussian noise property in the complex domain. It showed improvements in QSM reconstruction over the conventional field-to-source inversion. Methods The proposed mcTFI method was compared with the nonlinear total field inversion (nTFI) method in a numerical brain with hemorrhage and calcification, the numerical brains provided by the QSM Challenge 2.0, 18 brains with intracerebral hemorrhage scanned at 3T, and 6 healthy brains scanned at 7T. Results Compared with nTFI, the proposed mcTFI showed more accurate QSM reconstruction around the lesions in the numerical simulations. The mcTFI reconstructed QSM also showed the best image quality with the least artifacts in the brains with intracerebral hemorrhage scanned at 3T and healthy brains scanned at 7T. Conclusion The proposed multiecho complex total field inversion improved QSM reconstruction over traditional field-to-source inversion through better signal modeling.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据