4.4 Article

A multi-inversion-recovery magnetic resonance fingerprinting for multi-compartment water mapping

期刊

MAGNETIC RESONANCE IMAGING
卷 81, 期 -, 页码 82-87

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.mri.2021.06.005

关键词

Myelin; Brain MRI; Multi-contrast MRI; MR fingerprinting

资金

  1. Hong Kong HMRF [06172916, 07182706]

向作者/读者索取更多资源

This study introduced a new mIR MRF method to quantify different compartments of brain water at 3 T MRI, achieving differentiation between myelin water, gray matter water, and white matter water. The mIR scheme improved the detection of myelin water content compared to conventional techniques, and the 5 IR MRF showed fewer artifacts in myelin water detection.
Purpose: This study aimed at introducing short-T1/T2 compartment to MR fingerprinting (MRF) at 3 T. Water that is bound to myelin macromolecules have significantly shorter T1 and T2 than free water and can be distinguished from free water by multi-compartment analysis. Methods: We developed a new multi-inversion-recovery (mIR) water mapping-MRF based on an unbalanced steady-state coherent sequence (FISP). mIR pulses with an interval of 400 or 500 repetition times (TRs) were inserted into the conventional FISP MRF sequence. Data from our proposed mIR MRF was used to quantify different compartments, including myelin water, gray matter free water, and white matter free water, of brain water by virtue of the iterative non-negative least square (NNLS) with reweighting. Three healthy volunteers were scanned with mIR MRF on a clinical 3 T MRI. Results: Using an extended phase graph simulation, we found that our proposed mIR scheme with four IR pulses allowed differentiation between short and long T1/T2 components. For in vivo experiments, we achieved the quantification of myelin water, gray matter water, and white matter water at an image resolution of 1.17 & times; 1.17 & times; 5 mm3/pixel. As compared to the conventional MRF technique with single IR, our proposed mIR improved the detection of myelin water content. In addition, mIR MRF using spiral-in/out trajectory provided a higher signal level compared with that with spiral-out trajectory. Myelin water quantification using mIR MRF with 4 IR and 5 IR pulses were qualitatively similar. Meanwhile, 5 IR MRF showed fewer artifacts in myelin water detection. Conclusion: We developed a new mIR MRF sequence for the rapid quantification of brain water compartments.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据