4.4 Article

Time to maximum indocyanine green fluorescence of gastric sentinel lymph nodes and feasibility of combined indocyanine green/sodium fluorescein gastric lymphography

期刊

LANGENBECKS ARCHIVES OF SURGERY
卷 406, 期 8, 页码 2717-2724

出版社

SPRINGER
DOI: 10.1007/s00423-021-02265-y

关键词

Fluorescence lymphography; Indocyanine green; Quantification; Sodium fluorescein

类别

资金

  1. Department of Surgical Gastroenterology, Rigshospitalet research fund

向作者/读者索取更多资源

ICG lymphography significantly increased the number of resected lymph nodes in oncological gastric surgery. Intraoperative injections of ICG could be a sufficient alternative to preoperative injections due to the short time until maximum ICG fluorescence of sentinel lymph nodes. Combined ICG and SF lymphography was feasible and resulted in clear lymphograms with no interference between the two dyes, offering the exciting prospect of simultaneously assessing perfusion and performing fluorescence lymphography.
Purpose Indocyanine green (ICG) and sodium fluorescein (SF) are fluorescent dyes used for sentinel lymph node mapping. In oncological gastric surgery, ICG lymphography has increased the number of resected lymph nodes. However, the optimal time to administer ICG is unclear, and both preoperative and intraoperative injections have been practised. As dye spillage will diminish lymphogram visibility, a second dye with different excitation and emission spectra may present a clinical alternative. We measured the time until maximum ICG fluorescence of gastric sentinel lymph nodes and investigated the feasibility of combined lymphography with two fluorescent dyes: ICG and SF. Methods Ten Danish Landrace/Yorkshire pigs were used in this study. After completion of the laparoscopic setup, ICG and then SF were endoscopically injected into the gastric submucosa. Lymphograms for both dyes were recorded, and the time until maximum ICG sentinel lymph node fluorescence was determined. Results The mean time until maximum ICG fluorescence of gastric sentinel lymph nodes was 50 s (+/- 12.5), and the fluorescent signal then remained stable until the end of the recorded period (45 min). A lymphogram showing both ICG and SF was acquired for eight of the ten pigs. Conclusions Because of the short time until maximum ICG fluorescence of sentinel lymph nodes, intraoperative injections could be a sufficient alternative to preoperative injections for oncological gastric surgery. Combined ICG and SF lymphography was feasible and resulted in clear lymphograms with no interference between the two dyes. The ability to use multiple dyes during a surgical procedure offers the exciting prospect of simultaneously assessing perfusion and performing fluorescence lymphography.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据