Urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine analysis by an improved ELISA: An inter-laboratory comparison study

期刊

FREE RADICAL BIOLOGY AND MEDICINE
卷 95, 期 -, 页码 169-179

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.freeradbiomed.2016.03.016

关键词

8-OxodG; ELISA; HPLC-MS/MS; Inter-laboratory agreement; Oxidative stress; Standardization; Urine

资金

  1. GA CR [13-13458S, 16-146315]
  2. MEYS (the NPU I program) [LO1508]
  3. TOBiTAK [114S310]
  4. MZE [RO-0515]
  5. [ES009089]

向作者/读者索取更多资源

ELISA is commonly used for the detection of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG), a marker of whole body oxidative stress. However, the method has been criticized for high inter-laboratory variability and poor agreement with chromatographic techniques. We performed an inter-laboratory comparison of 8-oxodG assessed in 30 urine samples and a urine spiked with four different concentrations of 8-oxodG by ELISA using standardized experimental conditions, including: sample pretreatment with solid-phase extraction (SPE), performing analysis using a commercial kit from a single manufacturer and strict temperature control during the assay. We further compared the ELISA results with high-performance liquid chromatography-tandem mass spectrometry (HPLC MS/MS) and performed tentative identification of compounds that may contribute to the discrepancy between both methods. For all but one participating laboratory (Data 1) we observed consistent ELISA results lying mostly within 1 SD of the mean 8-oxodG concentration. Mean 8-oxodG levels assessed by ELISA correlated with the data obtained by HPLC MS/MS (R=0.679, p < 0.001). The correlation improved when Data 1 were excluded from the analysis (R=0.749, p < 0.001). We identified three outlying urine samples; one with an ELISA 8-oxodG concentration lower, and two with 8-oxodG levels higher, than those measured by HPLC MS/MS. Omitting these samples further improved inter-methodology agreement (R=0.869, p <0.001). In the outliers with high 8-oxodG estimates various aromatic and heterocyclic compounds were tentatively identified using gas chromatography-mass spectrometry (GC MS). Application of authentic standards revealed the presence of saccharides, including D-glucose and D-galactose as putative interfering substances. In summary, assay standardization improved ELISA inter-laboratory agreement, although some variability is still observed. There are still compounds contributing to overestimation of 8-oxodG by ELISA, but only in some urine samples. Thus, despite significant improvement, ELISA still should not be considered a robust alternative to chromatographic techniques. (C) 2016 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据