4.5 Article

Feasibility and Accuracy of Automated Three-Dimensional Echocardiographic Analysis of Left Atrial Appendage for Transcatheter Closure

期刊

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.echo.2021.08.023

关键词

Left atrial appendage closure; LAA device sizing; Automated software analysis; Interactive analysis; 3D transesophageal echocardiography

资金

  1. Northern Portugal Regional 124 [NORTE-01-0145-FEDER-000045, NORTE-01-0145-FEDER-000059]

向作者/读者索取更多资源

This study evaluated the feasibility and accuracy of a novel software tool for automated 3D analysis of the left atrial appendage (LAA) using 3D transesophageal echocardiographic data. The results showed that the automated software accurately determined the LAA size and had higher reproducibility and faster analysis compared to traditional 2D echocardiography.
Background: Procedural success of transcatheter left atrial appendage closure (LAAC) is dependent on correct device selection. Three-dimensional (3D) transesophageal echocardiography (TEE) is more accurate than the two-dimensional modality for evaluation of the complex anatomy of the left atrial appendage (LAA). However, 3D transesophageal echocardiographic analysis of the LAA is challenging and highly expertise dependent. The aim of this study was to evaluate the feasibility and accuracy of a novel software tool for automated 3D analysis of the LAA using 3D transesophageal echocardiographic data. Methods: Intraprocedural 3D transesophageal echocardiographic data from 158 patients who underwent LAAC were retrospectively analyzed using a novel automated LAA analysis software tool. On the basis of the 3D transesophageal echocardiographic data, the software semiautomatically segmented the 3D LAA structure, determined the device landing zone, and generated measurements of the landing zone dimensions and LAA length, allowing manual editing if necessary. The accuracy of LAA preimplantation anatomic measurement reproducibility and time for analysis of the automated software were compared against expert manual 3D analysis. The software feasibility to predict the optimal device size was directly compared with implanted models. Results: Automated 3D analysis of the LAA on 3D TEE was feasible in all patients. There was excellent agreement between automated and manual measurements of landing zone maximal diameter (bias,-0.32; limits of agreement,-3.56 to 2.92), area-derived mean diameter (bias,-0.24; limits of agreement,-3.12 to 2.64), and LAA depth (bias, 0.02; limits of agreement,-3.14 to 3.18). Automated 3D analysis, with manual editing if necessary, accurately identified the implanted device size in 90.5% of patients, outperforming twodimensional TEE (68.9%; P < .01). The automated software showed results competitive against the manual analysis of 3D TEE, with higher intra-and interobserver reproducibility, and allowed quicker analysis (101.9 +/- 9.3 vs 183.5 +/- 42.7 sec, P < .001) compared with manual analysis. Conclusions: Automated LAA analysis on the basis of 3D TEE is feasible and allows accurate, reproducible, and rapid device sizing decision for LAAC. (J Am Soc Echocardiogr 2022;35:124-33.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据