4.6 Article

Isocyanate derivatization coupled with phospholipid removal microelution-solid phase extraction for the simultaneous quantification of (S)-metoprolol and (S)-α-hydroxymetoprolol in human plasma with LC-MS/MS

出版社

ELSEVIER
DOI: 10.1016/j.jpba.2021.114263

关键词

Metoprolol; Phospholipid removal microelution-solid phase extraction; Isocyanate derivatization; LC-MS/MS; Chiral assay

向作者/读者索取更多资源

A sensitive LC-MS/MS assay was developed and validated for quantification of (S)-metoprolol and its metabolite in human plasma. The method showed stability and accuracy for clinical use, which could be further explored for investigating the clinical impact of (S)-MET concentrations.
A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated for the quantification of (S)-metoprolol (MET) and its main metabolite, (S)-alpha-hydroxymetoprolol (OH-MET). Human plasma samples (50 mu L) were spiked with both analytes and their deuterated internal standards (IS) (S)-MET-(d7) and alpha-OH-MET-(d5). Phospholipid removal microelution-solid phase extraction (PRM-SPE) was performed using a 4-step protocol with Oasis PRiME MCX mu Elution 96-well cartridges. The eluates were reconstituted in 100 mu L of acetonitrile with 50 mu gImL (S)-alpha-methylbenzyl isocyanate (MBIC) for chiral derivatization. After 60 min at room temperature, the reaction was quenched using 100 mu L of water 2 % formic acid. Chromatographic separation of the derivatized analytes was performed on a Kinetex phenyl-hexyl core-shell stationary phase with an elution gradient. Mobile phases were composed of a mixture of water and methanol, with ammonium formate and formic acid as buffers. Total runtime was 15 min. Analyte detection was performed by an AB/SCIEX 4000 QTRAP mass spectrometer with multiple reaction monitoring. Chromatograms showed MBIC successfully reacted with racemic MET, alpha-OH-MET, and their respective IS. Detection by positive electrospray ionization did not reveal derivatized by-products. Quantification ranges were validated for (S)-MET and (S)-alpha-OH-MET between 0.5-500 and 1.25-500 ng/mL, respectively, with correlation coefficients (r(2)) >0.9906. The PRM-SPE assay showed low matrix effects (86.9-104.0 %) and reproducible recoveries (69.4-78.7 %) at low, medium, and high quality control (QC) levels. Precision and accuracy were all comprised between 85-115 % for all three QCs, and between 80-120 % for the lower limit of quantification, for intra- and inter-day values (n = 6, 3 consecutive days). Non-derivatized analytes were stable at room temperature, after 3 freeze-thaw cycles, and stored for 30 days at -80 degrees C (n = 4). Reinjection reproducibility of a previously validated batch was achieved after 8 days under auto-sampler conditions, indicating the stability of (S)-MET and (S)-alpha-OH-MET derivatives. Its clinical use was established in a cohort of 50 patients and could be used to further investigate the clinical impact of (S)-MET concentrations. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据