4.1 Article

Virtual Analysis of Segmental Bimaxillary Surgery: A Validation Study

期刊

JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY
卷 79, 期 11, 页码 2320-2333

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.joms.2021.06.003

关键词

-

向作者/读者索取更多资源

This study proposed and validated an automated approach for 3D assessment of segmental bimaxillary surgery, showing excellent reliability in quantitative assessment of postoperative outcomes and accuracy on a group of subjects.
Purpose: Three-dimensional (3D) assessment of orthognathic surgery is often time consuming, relies on manual re-identification of anatomical landmarks or is limited to non-segmental osteotomies. The purpose of the present study was to propose and validate an automated approach for 3D assessment of the accuracy and postoperative outcome of segmental bimaxillary surgery. Methods: A semi-automatic approach was developed and validated for virtual surgical analysis (VSA) of segmental bimaxillary surgery using a pair of pre- and postoperative (2 weeks) cone-beam computerized tomography (CBCT) scans. The output of the VSA, the accuracy of the surgical outcome, was calculated as 3D translational and rotational differences between the planned and postoperative movements of the individual bone segments. To evaluate the reliability of the proposed VSA, intra-class correlation coefficients (ICC) were calculated at a 95% confidence interval on measurements of 2 observers. The VSA was deemed reliable if the ICC was excellent (> 0.80) and the absolute difference of the repeated intra-and inter-observer translational and rotational measurements were significantly lower (p < 0.05) than a hypothesized clinical relevant threshold of 1 voxel (0.45 mm) and 1 degree, respectively. Results: A total of 10 subjects (6 male; 4 women; mean age 24.4 years) with skeletal class 2 and 3, who underwent segmental bimaxillary surgery, 3-piece Le Fort I, bilateral sagittal split osteotomy and genioplasty, were recruited. The intra-and inter-observer reliability was excellent, ICC range [0.96 - 1.00]. The range of the mean absolute difference of the repeated intra-and inter-observer translational and rotational measurements were [0.07 mm (0.05) - 0.20 mm (0.19)] and [0.11 degrees (0.08) - 0.63 degrees (0.42)], respectively. This was significantly lower than the hypothesized clinical relevant thresholds (P < .001). Conclusion: The validation showed that the VSA has excellent reliability for quantitative assessment of the postoperative outcome and accuracy of segmental bimaxillary surgery. (C) 2021 Published by Elsevier Inc. on behalf of The American Association of Oral and Maxillofacial Surgeons.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据