The study found that P2Y12 hyporesponse was not associated with acute platelet aggregation or ischemic complications in patients undergoing Pipeline embolization of intracranial aneurysms. A greater Pipeline embolization device diameter was linked to a reduced odds of platelet aggregation, while antiplatelet non-compliance and treatment of posterior circulation aneurysms were the only independent predictors of ischemic complications.
Background The utility of using the VerifyNow P2Y12 platelet inhibition assay in patients undergoing Pipeline embolization of intracranial aneurysms remains controversial. As we have routinely employed the assay for patients undergoing flow diversion, we elected to explore the relationship between P2Y12 hyporesponse as indicated by a P2Y12 Reaction Units (PRU) value >200 and treatment outcomes, including intraprocedural platelet aggregation and ischemic complications. Methods All successful intracranial aneurysm Pipeline treatments performed at our institution from November 2011 to May 2019 were included. The rate of P2Y12 hyporesponse and treatment outcomes were evaluated. Multivariable logistic regression was utilized to determine independent predictors of treatment outcomes. Results 333 qualifying treatments were performed in 297 patients. Clopidogrel hyporesponse was initially noted in 24%, falling to 17% by day-of-procedure by dose titration. A glycoprotein (GP) IIb/IIIa inhibitor was administered prophylactically in 3% of cases for persistent, profound hyporesponse. 27 (8.1%) patients developed acute platelet aggregation; only 6 demonstrated day-of-procedure P2Y12 hyporesponse. Day-of-procedure hyporesponse was not associated with intraprocedural platelet aggregation or ischemic complications. Greater Pipeline embolization device (PED) diameter was associated with a reduced odds of platelet aggregation (OR 0.38, 95% CI 0.17 to 0.85; p=0.019). Antiplatelet non-compliance (OR 25.20, 95% CI 3.86 to 164.61; p=0.001) and treatment of posterior circulation aneurysms (OR 5.23, 95% CI 1.22 to 22.33; p=0.026) were the only independent predictors of ischemic complications. Conclusions P2Y12 hyporesponse was not associated with acute platelet aggregation or ischemic complications in our patients undergoing Pipeline embolization of intracranial aneurysms, possibly due to aggressive management of the hyporesponse using clopidogrel dose titration and/or GP IIb/IIIa inhibitor administration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据