4.7 Article

Efficacy comparison of three rapid antigen tests for SARS-CoV-2 and how viral load impact their performance

期刊

JOURNAL OF MEDICAL VIROLOGY
卷 93, 期 10, 页码 5783-5788

出版社

WILEY
DOI: 10.1002/jmv.27108

关键词

COVID-19; point-of-care testing; rapid antigen test; SARS-CoV-2

类别

向作者/读者索取更多资源

This study evaluated the performance of three rapid antigen tests for SARS-CoV-2 diagnosis under varying viral loads, showing higher sensitivities in samples with higher viral loads. However, the sensitivities of all three tests dropped significantly when viral loads decreased, with GSD NovaGen showing lower specificity. Although not suitable for routine testing in high throughput laboratories, these tests can still be useful in quickly identifying highly infectious patients and screening close contacts in environments without easy access to molecular tests.
More and more rapid antigen tests for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) appear in the market with varying performance. The sensitivity of these tests heavily depends on the viral load, extrapolated by the threshold cycle (Ct). It is therefore essential to verify their performance before their inclusion in routine. The Coronavirus Ag Rapid Test Cassette Bio-Rad, the GSD NovaGen SARS-CoV-2 (COVID-19) Antigen Rapid Test, and the Aegle Coronavirus Ag Rapid Test Cassette were evaluated on 199 samples: 150 fresh samples from the routine and positive in quantitative reverse-transcription polymerase chain reaction (RT-qPCR), nine fresh samples negative in RT-qPCR, and 40 frozen samples, taken before the discovery of SARS-CoV-2 but positive for other respiratory viruses. Positive RT-qPCR samples were categorized according to their Ct: Ct < 20 (18.7%), >= 20-< 25 (27.3%), >= 25-< 30 (18.7%), >= 30-35 (17.3%), and > 35 (18.0%). Sensitivities (95% confidence interval) for Ct below 25 were 95.7% (92.4-98.9), 97.1% (94.4-99.8), and 97.1% (94.4-99.8) for GSD NovaGen, Bio-Rad, and Aegle, respectively but drastically dropped when Ct exceeded 27. Among samples with previously diagnosed viruses, seven false-positive results were found with GSD NovaGen only (specificity 85.7%). Equivalent, high sensitivities were observed with the highest viral load samples. The GSD NovaGen assay showed less specificity. Although the three kits tested in this study are inadequate for routine testing in a high throughput laboratory, they can help to quickly identify the most infectious patients and screen their close contacts in an environment where molecular tests are not readily available.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据