4.7 Article

Tellurite Hollow-Core Antiresonant Fiber-Coupled Quantum Cascade Laser Absorption Spectroscopy

期刊

JOURNAL OF LIGHTWAVE TECHNOLOGY
卷 39, 期 17, 页码 5662-5668

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JLT.2021.3088140

关键词

Quantum cascade lasers; Absorption; Optical fiber sensors; Spectroscopy; Gas lasers; Laser beams; Optical fibers; Absorption spectroscopy; gas sensor; hollow-core antiresonant fiber; mid-infrared; tellurite

资金

  1. Natural Science Foundation of Guangdong Province, China [2019A1515011372]
  2. University Grants Committee [14209220]
  3. Innovation and Technology Fund of Hong Kong SAR, China [ITS/242/19]
  4. project Lightpipe from the European Research Council [682724]
  5. Royal Society through Newton International Fellowship [NF170629]
  6. EPSRC Airguide Photonics Programme [EP/P030181/1]

向作者/读者索取更多资源

This study demonstrates the use of a quantum cascade laser coupled with a custom-made tellurite hollow-core antiresonant fiber for mid-infrared absorption spectroscopy for gas detection. Through direct absorption spectroscopy and wavelength modulation spectroscopy, it achieves high detection accuracy and sensitivity, particularly for nitric oxide (NO) detection.
Mid-infrared absorption spectroscopy for gas detection is reported in this study using a quantum cascade laser (QCL) coupled with a custom-made tellurite hollow-core antiresonant fiber (HC-ARF). The HC-ARF is fabricated from tellurite glass by extrusion and subsequent fiber drawing. The QCL emitting at 5.26 mu m is coupled into the 21-cm long HC-ARF. As a proof-of-concept, this spectroscopic system is demonstrated for nitric oxide (NO) detection by exploiting its strong absorption line at 1900.08 cm(-1). By quickly filling gas mixtures into the HC-ARF, we first conduct direct absorption spectroscopy of NO and achieve a noise equivalent absorption (NEA) of 2.1 x 10(-5) cm(-1). Besides, we also conduct wavelength modulation spectroscopy to improve sensing performance. A minimum detection limit of 6 ppb NO is achieved at the integration time of 30 s, corresponding to 1.0 x 10(-7) cm(-1) in NEA. The HC-ARF is tested to show a response time of only 0.3 s when applying a pressure difference of 11 kPa between the two fiber ends. Such a tellurite HC-ARF-coupled QCL spectroscopic system makes it attractive for developing optical gas sensors with compact size, fast response, and high sensitivity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据