The study aimed to monitor water quality in commercial packinghouse flume tanks and evaluate the efficacy of postharvest washing of tomatoes. Results showed deterioration of water quality in all packinghouses over time, but postharvest washing did not have a significant effect on the microbiological qualities of tomatoes.
Monitoring and maintenance of water quality in dump tanks or flume systems is crucial to maintaining proper sanitizer levels to prevent pathogen cross-contamination during postharvest washing of tomatoes, but there is limited information on how organic matter influences sanitizer efficacy in the water. The main objective of this study was to monitor water quality in flume tanks and evaluate the efficacy of postharvest washing of tomatoes in commercial packinghouses. Flume tank water samples (n = 3) were collected on an hourly basis from three packinghouses in Florida and analyzed for pH, total dissolved solids (TDS), free chlorine, chemical oxygen demand (COD), oxidation-reduction potential, and turbidity. Additionally, three flume-water samples were collected and tested for total aerobic plate count (APC), total coliforms (TC), and Escherichia coli. Fresh tomatoes (n = 3), both before and after washing, were collected and analyzed for the same bacterial counts. Turbidity, COD, and TDS levels in flume water increased over time in all packinghouses. Correlations observed include COD and turbidity (r = 0.631), turbidity and TDS (r = 0.810), and oxidation-reduction potential and chlorine (r = 0.660). APC for water samples had an average range of 0.0 to 4.7 log CFU/mL and TC average range of 0.0 to 4.7 log CFU/mL. All water samples were negative for E. coli. The average APC for pre-and postflume tomatoes from the three packinghouses was 6.0 log CFU per tomato and ranged from 2.2 to 7.4 log CFU per tomato. The average TC count was ,1.5 and 7.0 log CFU per tomato for pre-and postwash tomatoes, respectively. There was no significant effect (P > 0.05) of postharvest washing on the microbiological qualities of tomatoes. Water quality in flume tanks deteriorated over time in all packinghouses during a typical operational day of 4 to 8 h.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据