4.6 Article

Benchmark of thirteen bioinformatic pipelines for metagenomic virus diagnostics using datasets from clinical samples

期刊

JOURNAL OF CLINICAL VIROLOGY
卷 141, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.jcv.2021.104908

关键词

Viral metagenomics; Benchmark; Bioinformatic pipelines

类别

资金

  1. Clinical Research Priority Program 'Comprehensive Genomic Pathogen Detection' of the University of Zurich
  2. Instituto de Salud Carlos III, Spain [PI18/01824, PI18/01759]

向作者/读者索取更多资源

This study evaluated the performance and characteristics of different viral metagenomic pipelines used in clinical virological laboratories, showing that the pipelines performed well in detecting high load viral pathogens but struggled with low abundance pathogens and mixed infections. Standardization and validation of metagenomic analysis for clinical diagnostic use are needed to address these challenges.
Introduction: Metagenomic sequencing is increasingly being used in clinical settings for difficult to diagnose cases. The performance of viral metagenomic protocols relies to a large extent on the bioinformatic analysis. In this study, the European Society for Clinical Virology (ESCV) Network on NGS (ENNGS) initiated a benchmark of metagenomic pipelines currently used in clinical virological laboratories. Methods: Metagenomic datasets from 13 clinical samples from patients with encephalitis or viral respiratory infections characterized by PCR were selected. The datasets were analyzed with 13 different pipelines currently used in virological diagnostic laboratories of participating ENNGS members. The pipelines and classification tools were: Centrifuge, DAMIAN, DIAMOND, DNASTAR, FEVIR, Genome Detective, Jovian, MetaMIC, MetaMix,One Codex, RIEMS, VirMet, and Taxonomer. Performance, characteristics, clinical use, and user-friendliness of these pipelines were analyzed. Results: Overall, viral pathogens with high loads were detected by all the evaluated metagenomic pipelines. In contrast, lower abundance pathogens and mixed infections were only detected by 3/13 pipelines, namely DNASTAR, FEVIR, and MetaMix. Overall sensitivity ranged from 80% (10/13) to 100% (13/13 datasets). Overall positive predictive value ranged from 71-100%. The majority of the pipelines classified sequences based on nucleotide similarity (8/13), only a minority used amino acid similarity, and 6 of the 13 pipelines assembled sequences de novo. No clear differences in performance were detected that correlated with these classification approaches. Read counts of target viruses varied between the pipelines over a range of 2-3 log, indicating differences in limit of detection. Conclusion: A wide variety of viral metagenomic pipelines is currently used in the participating clinical diagnostic laboratories. Detection of low abundant viral pathogens and mixed infections remains a challenge, implicating the need for standardization and validation of metagenomic analysis for clinical diagnostic use. Future studies should address the selective effects due to the choice of different reference viral databases.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据