4.7 Article

The Usefulness of Two CXCL13 Assays on Cerebrospinal Fluid for the Diagnosis of Lyme Neuroborreliosis: a Retrospective Study in a Routine Clinical Setting

期刊

JOURNAL OF CLINICAL MICROBIOLOGY
卷 59, 期 9, 页码 -

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.00255-21

关键词

Borrelia; Lyme neuroborreliosis; cerebrospinal fluid; CXCL13; Reibergram; blood-CSF barrier functionality; intrathecal antibody synthesis

资金

  1. Dutch Ministry of Health, Welfare and Sports

向作者/读者索取更多资源

Recent studies have shown elevated levels of CXCL13 in the CSF of patients with early Lyme neuroborreliosis. The Quantikine CXCL13 ELISA and recomBead CXCL13 assay were found to be sensitive and specific in diagnosing LNB, with potential additional value in the diagnostic process.
Recent studies have shown elevated levels of the B-cell chemokine (C-X-C motif) ligand 13 (CXCL13) in the cerebrospinal fluid (CSF) of patients with early Lyme neuroborreliosis (LNB). In this retrospective study, we evaluated the diagnostic performance of the Quantikine CXCL13 enzyme-linked immunosorbent assay (ELISA) (R&D Systems, Inc., MN, USA) and the recomBead CXCL13 assay (Mikrogen, Neuried, Germany) for the detection of CXCL13 in CSF. All consecutive patients from whom a CSF and a serum sample had been collected between August 2013 and June 2016 were eligible for inclusion. Patients suspected of LNB were classified as definite, possible, or non-LNB according to the guidelines of the European Federation of Neurological Societies (EFNS). Due to the limited number of LNB patients in the predefined study period, additional LNB patients were included from outside this period. In total, 156 patients (150 consecutive patients and 6 additional LNB patients) were included. Seven (4.5%) were classified as definite, eight (5.1%) as possible, and 141 (90.4%) as non-LNB patients. Receiver operating characteristic (ROC) curve analysis comparing definite-LNB patients with non-LNB patients showed a cutoff value of 85.9 pg/ml for the Quantikine CXCL13 ELISA and 2522 pg/ml for the recomBead CXCL13 assay. The corresponding sensitivity was 100% (95% confidence interval [CI], 100% to 100%) for both, and the corresponding specificities were 98.6% (95% CI, 96.5% to 100%) for the CXCL13 ELISA and 97.2% (95% CI, 93.6% to 100%) for the recomBead CXCL13 assay. This study showed that CXCL13 in CSF can be of additional value for the diagnosis of LNB.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据