4.5 Article

Simultaneous determination of dacomitinib and its major metabolite, O-desmethyl dacomitinib in human plasma by LC-MS/MS and its application to clinical testing in patients with non-small cell lung cancer

出版社

ELSEVIER
DOI: 10.1016/j.jchromb.2021.122940

关键词

Dacomitinib; O-desmethyl dacomitinib; Human plasma; HPLC-MS/MS

资金

  1. National Major Scientific and Technological Special Project for Significant New Drugs Development [2017ZX09304022]

向作者/读者索取更多资源

A rapid and sensitive bioanalytical technique was established and fully validated for simultaneous quantification of dacomitinib and its main metabolite in human plasma, ensuring accuracy and precision within specified concentration ranges. The method satisfied regulatory requirements and demonstrated clinical applicability in treated patients.
Dacomitinib, an irreversible pan-ErbB tyrosine kinase inhibitor targeting the human epidermal growth factor receptor, is used for the treatment of metastatic non-small cell lung cancer. To facilitate the investigations on its metabolism and other relevant studies, based on high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), a rapid and sensitive bioanalytical technique was established and fully validated for simultaneous quantification of dacomitinib and its main metabolite in human plasma. The plasma samples were treated with acetonitrile containing 0.1% formic acid and the liquid supernatant was collected, dried and dissolved in methanol-water-formic acid (200:800:1, v/v) before injection. The chromatographic separation was performed on an ACE Excel C-18 column (2.1 mm x 50.0 mm, i.d., 5 mu m) by gradient elution with a mixture of buffer (5 mM ammonium acetate in 0.1% formic acid) and acetonitrile, serving as the mobile phase, with an overall run time of 4 min. Dacomitinib, O-desmethyl dacomitinib and IS were subsequently detected on an AB QTRAP 5500 mass spectrometer in positive ion and multiple reaction monitoring modes at the precursor-to product transitions of m/z 470.4 -> 385.0, m/z 456.0 -> 370.9 and m/z 480.2 -> 385.1, respectively. The accuracy and precision of determinations were guaranteed within the concentration ranges of 0.25-100 ng/mL for dacomitinib and 0.20-80 ng/mL for O-desmethyl dacomitinib. The intra-and inter-assay accuracy ranged from 92.00% to 104.50% and the intra-and inter-assay precision was less than 8.20% for each analyte. The method was validated and the relevant parameters, including selectivity, interference among analytes and internal standard, carry-over effect, dilution integrity, extraction recovery, matrix effect, and stability, all satisfied the requirements formulated by the US Food and Drug Administration and the European Medicines Agency. The clinical applicability of the fully-validated method was evaluated in medicated samples from patients on dacomitinib.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据