4.6 Article

Ultrasensitive determination of serotonin in human urine by a two dimensional capillary isotachophoresis-capillary zone electrophoresis hyphenated with tandem mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1648, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2021.462190

关键词

Capillary isotachophoresis; Capillary electrophoresis; Column coupling arrangement; Tandem mass spectrometry; Serotonin; Human urine

资金

  1. [VEGA 1/0463/18]
  2. [KEGA 027UK-4/2020]
  3. [APVV-15-0585]
  4. [VEGA 2/0088/18]
  5. [VEGA 2/0150/19]
  6. [APVV-18-0302]

向作者/读者索取更多资源

A two-dimensional capillary isotachophoresis-capillary zone electrophoresis method hyphenated with tandem mass spectrometry was developed and validated for ultrasensitive quantification of serotonin in real human urine samples. This method demonstrated high precision, accuracy, and recovery rates, making it suitable for routine clinical screening or targeted metabolomic studies of serotonin in urine samples. The advanced method showed promising potential for effective and reliable analysis of serotonin levels in urine samples.
A two-dimensional capillary isotachophoresis-capillary zone electrophoresis method hyphenated with tandem mass spectrometry was developed and validated for ultrasensitive quantification of serotonin in real human urine samples. Under optimal conditions, the separation was achieved within 12 min (including on-line sample preparation) with the limit of detection of 34 pg mL -1 (due to a large volume sample injection, here 10 mu L, and isotachophoretic preconcentration). This concentration limit represents the lowest value for serotonin in comparison to other previously published separation methods employing mass spectrometry detection and applied to urine matrices. Thanks to high orthogonality, on-line concentration and clean-up effects of this approach, other excellent validation parameters such as linearity (coefficient of determination > 0.99), inter-day and intra-day precision (relative standard deviations 3.5-12.2%), accuracy (relative errors within 99-109.4%), and recovery (96-102%) could be easily obtained too. To demonstrate applicability of the method, we monitored serotonin levels in various real samples (from a healthy volunteer and clinical ones). The determined levels, normalized on the creatinine concentrations, were in the range of 6.81-12.86 ng mmol -1 creatinine This advanced method is suggested for an effective, reliable, high sample throughput, and low cost routine clinical screening or targeted metabolomic studies of serotonin in urine samples. (c) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据