4.6 Article

Effects of amino acid-derived chiral ionic liquids on cyclodextrin-mediated capillary electrophoresis enantioseparations of dipeptides

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1652, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2021.462342

关键词

Chiral ionic liquids; Cyclodextrin; Enantioseparation; Dipeptides; Synergistic effect

向作者/读者索取更多资源

The study investigated the synergistic effect of chiral ionic liquids composed of tetraalkylammonium ions and amino acids on the enantioseparations of dipeptides in capillary electrophoresis. It was found that the presence of a chiral ionic liquid can enhance the enantioresolutions, but the extent of enhancement varies with the composition, concentration, and stereochemistry of the components.
The synergistic effect of chiral ionic liquids composed of tetraalkylammonium ions and the amino acids Asn, Asp or Pro on the enantioseparations of dipeptides mediated by beta-cyclodextrin and 2-hydroxypropyl-beta-cyclodextrin in capillary electrophoresis was studied. Addition of a chiral ionic liquid resulted in a concentration-dependent increase in the enantioresolutions compared to the sole presence of a cyclodextrin in the background electrolyte. The extent varied with the tetraalkylammonium cation (tetramethylammonium versus tetrabutylammonium) as well as the amino acid component of the ionic liquid. The presence of a chiral ionic liquid did not counteract the pH-dependent reversal of the enantiomer migration order of the dipeptides Ala-Phe, Ala-Tyr and Phe-Phe when increasing the pH of the background electrolyte from 2.5 to 3.5. Comparing the effect of a chiral ionic liquid based on Asp with the addition of equimolar concentrations of the individual components of the ionic liquid, a diverse picture was observed. In some cases, higher resolution values were obtained with the chiral ionic liquid, while for other cases superior enantioseparations were obtained upon separate addition of the amino acid component and a tetraalkylammonium chloride. With regard to the stereochemistry of the amino acid, a superior effect was typically observed using the L-configured amino acid, but in some cases higher resolution values were found in the presence of D-Asp. The rationale for the diverse observations is not obvious and may be due to the zwitterionic nature of analytes as well as the amino acid component of the chiral ionic liquid. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据