4.6 Article

A method for the analysis of 121 multi-class environmental chemicals in urine by high-performance liquid chromatography-tandem mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1646, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2021.462146

关键词

Endocrine disruptors; Human biomonitoring; Urine; LC-MS/MS; Multi-class method; Exposome

资金

  1. National Institute of Environmental Health Sciences (NIEHS) [U2CES026542]

向作者/读者索取更多资源

The study introduces a method for monitoring 121 environmental chemicals in urine samples using solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The optimized method showed excellent variability, satisfactory recoveries, and high detection limits for a wide range of analytes. This validated method was successfully applied to the simultaneous determination of environmental chemicals in real urine samples.
Biomonitoring of human exposure to environmental chemicals has gained momentum in recent years. Biomonitoring methods often include analysis of a single class of chemicals with similar chemical properties. In this study, we describe a method that involves solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and capable of measuring 121 environmental chemicals comprising plasticizers (PMs; n = 45), environmental phenols (EPs; n = 45), and pesticides (n = 31) through a single extraction of urine. Urine samples were incubated with 20 mu L of beta-glucuronidase/arylsulfatase (40 00 units/mL urine) (from Helix pomatia) buffered at pH 5.5 for 2 h at 37 degrees C for optimal deconjugation conditions. We compared two extraction methods, namely liquid-liquid extraction and SPE, and the latter with ABS Elut NEXUS (R) cartridges was optimized to yield best extraction efficiencies. For increased resolution and chromatographic separation, two methods involving Ultra AQ C18 (R) and Betasil (TM) C18 (R) columns were used. The MS/MS analyses were performed under both negative and positive ionization modes. The optimized method yielded excellent intra- and inter-day variabilities (relative standard deviation: 0.40-11%) and satisfactory recoveries (80-120%) for >95% of the analytes. The limits of detection were <= 0.1 ng/mL for 101 analytes and between 0.1 and 1.0 ng/mL for 18 analytes. The optimized SPE LC-MS/MS method was validated through the analysis of standard reference materials and proficiency test urine samples and further applied in the analysis of 21 real urine samples to demonstrate simultaneous determination of 121 environmental chemicals in urine samples. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据