4.5 Article

The effect of hypochlorous acid on the tribocorrosion of CoCrMo/Ti-6Al-4V bearing couples

期刊

JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A
卷 109, 期 12, 页码 2536-2544

出版社

WILEY
DOI: 10.1002/jbm.a.37248

关键词

arthroplasty; inflammation; metal-on-metal devices; total joint; tribocorrosion

资金

  1. DePuy Synthes
  2. Hansjorg Wyss Endowment
  3. South Carolina SmartState Program

向作者/读者索取更多资源

The study found that under conditions of severe inflammation, the friction currents of metallic orthopedic alloys increased, depending on the energy released and the concentration of hypochlorous acid. The concentration of hypochlorous acid affected the fluctuations in friction current, as the oxidative power of the solution led to the regeneration of an oxide film, possibly resulting in increased release of oxide particles.
Mechanically assisted corrosion (MAC) of metallic orthopedic alloys is a consequence of the use of modular devices where opposing metal surfaces are tightly mated and loaded at the taper junction. MAC processes are affected by material surface characteristics and local solution chemistry. During inflammation, active immune cells may generate reactive oxygen species (such as hypochlorous acid [HOCl]) adjacent to surfaces undergoing micromotion, which may affect the tribocorrosion behavior of an implanted device. This study investigated the fretting current response of CoCrMo/Ti-6Al-4 V couples in a pin-on-disk apparatus utilizing HOCl solutions as a proxy for a severe inflammatory environment. Testing in 1 and 5 mM HOCl solutions were shown to generate a threefold and fivefold increase (p < 0.01), respectively, in fretting currents over pH 7.4 phosphate-buffered saline control conditions. Fretting currents were shown to be dependent on the energy dissipated during fretting and the concentration of HOCl where the currents within a single HOCl concentration were linearly dependent of energy dissipated, but different HOCl levels shifted (increased and then decreased) fretting currents with concentration. Fretting currents, governed by regrowth of an abraded oxide film, were affected by the oxidative power of the solution, which caused positive shifts in open circuit potential and likely resulted in a thicker oxide for 1 mM and 5 mM and fell with 30 mM. Small amounts of HOCl release within a joint may result in increased release of tribocorrosion products such as oxide particles.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据