4.5 Review

Distraction forces on the spine in early-onset scoliosis: A systematic review and meta-analysis of clinical and biomechanical literature

期刊

JOURNAL OF BIOMECHANICS
卷 124, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jbiomech.2021.110571

关键词

Early-onset scoliosis; Biomechanics; Distraction; Growing rods; Spine; Safety

向作者/读者索取更多资源

This study identified safety limits for pediatric spine distraction through a systematic review and meta-analysis, with in-vivo studies showing average distraction forces ranging from 242 to 621 N when using pedicle screw constructs. Ex-vivo studies demonstrated that segment C0-C2 was the strongest, with strength decreasing in more distal segments.
Distraction-based growing rods are frequently used to treat Early-Onset Scoliosis. These use intermittent spinal distractions to maintain correction and allow for growth. It is unknown how much spinal distraction can be applied safely. We performed a systematic review and meta-analysis of clinical and biomechanical literature to identify such safety limits for the pediatric spine. This systematic review and meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Three systematic searches were performed including in-vivo, ex-vivo and in-silico literature. Study quality was assessed in all studies and data including patient- or specimen characteristics, distraction magnitude and spinal failure location and ultimate force at failure were collected. Twelve studies were included, 6 in-vivo, 4 ex-vivo and 2 in-silico studies. Mean in-vivo distraction forces ranged between 242 and 621 N with maxima of 422-981 N, without structural failures when using pedicle screw constructs. In the ex-vivo studies (only cervical spines), segment C0-C2 was strongest, with decreasing strength in more distal segments. Meta-regression analysis demonstrated that ultimate force at birth is 300-350 N, which increases approximately 100 N each year until adulthood. Ex-vivo and in-silico studies showed that yielding occurs at 70-90% of ultimate force, failure starts at the junction between endplate and intervertebral disc, after which the posterior- and anterior long ligament rupture. While data on safety of distraction forces is limited, this systematic review and meta-analysis may aid in the development of guidelines on spinal distraction and may benefit the development and optimization of contemporary and future distractionbased technologies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据