Evolved gas analysis-mass spectrometry in an oxidative atmosphere using a temperature-programmable furnace-type pyrolyzer

期刊

出版社

ELSEVIER
DOI: 10.1016/j.jaap.2021.105122

关键词

Evolved gas analysis; EGA-MS; Temperature-programmable pyrolyzer; Air atmosphere; Thermo-oxidative decomposition; Polystyrene

向作者/读者索取更多资源

Evolved gas analysis-mass spectrometry (EGA-MS) was used to characterize the effects of heating materials in oxidative and non-oxidative environments. By modifying the gas inlet system, experiments under oxidative conditions in air could be conducted without loss of sensitivity. The modified method showed improved signal-to-noise ratio and comparable results when analyzing polystyrene and isotactic polypropylene.
Evolved gas analysis-mass spectrometry (EGA-MS) has been used to characterize the effect of heating a material in an oxidative or non-oxidative environment. Measurements in an oxidative environment are usually done by using the mixture of air and helium (He) as the carrier gas; however, ionization efficiency of evolved gases in a mass detector (MSD) decreases in such an environment, resulting in a corresponding decrease in sensitivity. The drop in sensitivity can be reduced by diluting the air in the carrier gas with He after evolving gases from a sample and before the evolved gases flow to the MSD. This study reports on a simple modification of the gas inlet system so that experiments requiring oxidative conditions in an air atmosphere can be routinely performed without loss of the MSD sensitivity. The impact of using this modification on the data is demonstrated using polystyrene (PS) as a test sample. EGA curves were acquired in two flow configurations: (1) adding He to the carrier gas immediately after the furnace, which reduces the concentration of nitrogen and oxygen in the carrier gas; thus, minimizing the quenching of the ionization and the associated decrease in signal-to-noise ratio (S/N) and (2) the standard configuration which simply uses a mixture of He and air as the carrier gas. Data obtained using the modified method had a much high S/N than that obtained using a gas mixture (He and air or He and oxygen) as a carrier gas. The RSD (n = 5) values for the peak area and the peak temperature of the EGA curve of PS were 1.6 and 0.60 % respectively, and these values were comparable with those obtained using a He carrier gas. The modified gas inlet system was also applied to the analysis of isotactic polypropylene.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据