4.4 Article

Systematic usability evaluation on two harnesses for a wearable chairless exoskeleton

出版社

ELSEVIER
DOI: 10.1016/j.ergon.2021.103162

关键词

CEX; Harness usability test; Wearable robot; Exoskeleton; Lower extremities; Harness improvement proposal

资金

  1. Ministry of Trade, Industry, and Energy (MOTIE)
  2. Korea Institute for Advancement of Technology (KIAT) of the Republic of Korea [N0002430]
  3. Ministry of Science and ICT of the Republic of Korea
  4. Science and Technology Policy Professional Manpower Nurturing and Support Project [N2020-0295]
  5. Korea Evaluation Institute of Industrial Technology (KEIT) [N0002430] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

This study compared and analyzed the usability of two harnesses for the Hyundai chairless exoskeleton (CEX), finding that the latter harness scored higher in wearability and overall satisfaction compared to the previous harness. The results provide valuable insights for future improvements in harness design for wearable robots.
Harnesses are used in wearable robots in safety, sports, medical, and industrial environments. Wearable robot harnesses for lower extremities should be designed to prevent musculoskeletal disorders caused by excessive strain on the spine and lower extremities when users wear these robots for prolonged periods. Therefore, this study compares and analyzes the usability of the two harnesses & mdash;the former (old design) and the latter (new design)& mdash;for the Hyundai chairless exoskeleton (CEX). In total, 27 participants took part in this study. The wearability, stability, and overall wearing satisfaction of the former and the latter harnesses were compared. We conducted an experiment where the participants wore the former and the latter harnesses while completing a series of tasks that resembled the ones performed by the workers on a front-end module assembling line of an automobile factory. After the experiment, the participants took part in a survey and semi-structured interviews. The data was analyses by t-test, correlation, and regression analyses. The survey results demonstrated that for the latter harness the cushioning sensation (thigh r = 0.539; calf r = 0.516) had the strongest effect on the overall wearing satisfaction. In addition, the latter harness scored higher in overall wear satisfaction than the previous harness. This study was able to verify the difference between the new and old designs according to the usability evaluation of the harness. The results of this study are considered to be helpful in design to improve the usability of the harness in the future.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据