4.8 Article

A 50-kW Three-Channel Wireless Power Transfer System With Low Stray Magnetic Field

期刊

IEEE TRANSACTIONS ON POWER ELECTRONICS
卷 36, 期 9, 页码 9941-9954

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2021.3064373

关键词

Couplings; Magnetic fields; Windings; Safety; Magnetic shielding; Magnetic noise; Rectifiers; Wireless power transfer; inductive power transfer; multi-channel WPT

资金

  1. National Natural Science Foundation of China [51807174]

向作者/读者索取更多资源

This article explores the potential of multichannel wireless power transfer systems for high-power transmission, allowing for adaptability to different power levels and cooperation between channels to achieve superior performance. By designing a three-channel system and adjusting power-sharing proportions, significant reductions in stray magnetic fields and improved efficiency can be achieved.
Adopting high-power wireless charging systems, particularly for heavy-duty electric vehicles (EVs) and fast charging of regular EVs, becomes extremely imperative. The stringent requirements of safety guidelines, high efficiency, and high-power density would continue to impede the rapid penetrations of wireless power transfer (WPT) systems for EVs at high power. This article investigates the potentials of multichannel WPT systems to achieve high-power transmission under such requirements. A multichannel WPT system consists of multiple power-transfer paths such that adjusting the number of channels affords the system become adaptive to multiple power levels that could eventually present an opportunity for developing high power, which would be seriously challenging with the conventional single-channel systems. Moreover, different channels can cooperate to achieve superior performance, such as a low stray magnetic field. A three-channel WPT system is designed in this article, and its capability of significantly reducing the stray magnetic field is investigated. By properly determining the power-sharing proportion of the channels, the magnetic field reduction of 80% and 63% can be achieved compared with the rectangular-pad and double D (DD) pad systems (under similar total pads area), respectively. A three-channel 50-kW prototype is produced with a dc-dc efficiency of 95.2% across the 160 mm air gap. The measured results of the magnetic field agree well with the simulation ones.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据