4.7 Article

Improving the efficacy and reliability of rTMS language mapping by increasing the stimulation frequency

期刊

HUMAN BRAIN MAPPING
卷 42, 期 16, 页码 5309-5321

出版社

WILEY
DOI: 10.1002/hbm.25619

关键词

brain stimulation; error rate; noninvasive; pain; picture naming; speech mapping; TMS; tolerability; virtual lesion

资金

  1. Deutsche Forschungsgemeinschaft [INST 1850/50-1]
  2. Universitat zu Koln [Gerok 8/2016]

向作者/读者索取更多资源

Systematically testing the influence of different stimulation frequencies on language mapping, this study found that 30 Hz rTMS induced significantly more errors compared to 50 Hz, while error rates were comparable with 10 Hz. The error rate was higher in Session 1 compared to Session 2, and reliability between sessions was poor for 10 and 30 Hz, but moderate for 50 Hz.
Repetitive TMS (rTMS) with a frequency of 5-10 Hz is widely used for language mapping. However, it may be accompanied by discomfort and is limited in the number and reliability of evoked language errors. We, here, systematically tested the influence of different stimulation frequencies (i.e., 10, 30, and 50 Hz) on tolerability, number, reliability, and cortical distribution of language errors aiming at improved language mapping. 15 right-handed, healthy subjects (m = 8, median age: 29 yrs) were investigated in two sessions, separated by 2-5 days. In each session, 10, 30, and 50 Hz rTMS were applied over the left hemisphere in a randomized order during a picture naming task. Overall, 30 Hz rTMS evoked significantly more errors (20 +/- 12%) compared to 50 Hz (12 +/- 8%; p <.01), whereas error rates were comparable between 30/50 and 10 Hz (18 +/- 11%). Across all conditions, a significantly higher error rate was found in Session 1 (19 +/- 13%) compared to Session 2 (13 +/- 7%, p <.05). The error rate was poorly reliable between sessions for 10 (intraclass correlation coefficient, ICC = .315) and 30 Hz (ICC = .427), whereas 50 Hz showed a moderate reliability (ICC = .597). Spatial reliability of language errors was low to moderate with a tendency toward increased reliability for higher frequencies, for example, within frontal regions. Compared to 10 Hz, both, 30 and 50 Hz were rated as less painful. Taken together, our data favor the use of rTMS-protocols employing higher frequencies for evoking language errors reliably and with reduced discomfort, depending on the region of interest.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据