4.5 Article

Accuracy assessment of pedicle screw insertion with patient specific 3D-printed guides through superimpose CT-analysis in thoracolumbar spinal deformity surgery

期刊

EUROPEAN SPINE JOURNAL
卷 30, 期 11, 页码 3216-3224

出版社

SPRINGER
DOI: 10.1007/s00586-021-06951-9

关键词

3D-printed guides; Pedicle screws; Superimpose CT-analysis; Spinal deformity surgery

向作者/读者索取更多资源

This study demonstrates the accuracy of drill guide assisted pedicle screw placement in thoracolumbar spinal deformity surgery by superimpose CT-analysis. Results show that all screws were positioned within the safe zone, with a mean linear deviation of 0.92 mm and mean angular deviation of 2.92 degrees. The patient specific 3D-printed guide technology is recommended as a safe and accurate tool for precise pedicle screw insertion.
Purpose In order to avoid pedicle screw misplacement in posterior spinal deformity surgery, patient specific 3D-printed guides can be used. An accuracy assessment of pedicle screw insertion can be obtained by superimposing CT-scan images from a preoperative plan over those of the postoperative result. The aim of this study is to report on the accuracy of drill guide assisted pedicle screw placement in thoracolumbar spinal deformity surgery by means of a superimpose CT-analysis. Methods Concomitant with the clinical introduction of a new technique for drill guide assisted pedicle screw placement, the accuracy of pedicle screw insertion was analyzed in the first patients treated with this technique by using superimpose CT-analysis. Deviation from the planned ideal intrapedicular screw trajectory was classified according to the Gertzbein scale. Results Superimpose CT-analysis of 99 pedicle screws in 5 patients was performed. The mean linear deviation was 0.92 mm, the mean angular deviation was 2.92 degrees with respect to the preoperatively planned pedicle screw trajectories. According to the Gertzbein scale, 100% of screws were found to be positioned within the safe zone. Conclusion The evaluated patient specific 3D-printed guide technology was demonstrated to constitute a safe and accurate tool for precise pedicle screw insertion in spinal deformity surgeries. Superimpose CT-analysis showed a 100% accuracy of pedicle screw placement without any violation of the pedicle wall or other relevant structures. We recommend a superimpose CT-analysis for the first consecutive patients when introducing new technologies into daily clinical practice, such as intraoperative imaging, navigation or robotics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据