4.4 Article

Age, minimum alveolar concentration and choice of depth of sedation monitor: examining the paradox of age when using the Narcotrend monitor A secondary analysis of an observational study

期刊

EUROPEAN JOURNAL OF ANAESTHESIOLOGY
卷 39, 期 4, 页码 305-314

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/EJA.0000000000001576

关键词

-

资金

  1. Bangerter-Rhyner Foundation
  2. Clinical Trials Unit of the University Hospital of Bern, University of Bern
  3. Department of Anaesthesiology and Pain Medicine, Bern University Hospital, University of Bern, Bern, Switzerland

向作者/读者索取更多资源

With an aging global population, it is important to customize the dosing of anesthetics according to age and their effects on the brain. A recent study observed that the concentration of volatile anesthetics during general surgery decreases by around 3% per age-decade, which is less than the expected decrease of 6% based on age-adjusted values. Paradoxically, despite the excessive dosing, the Bispectral index (BIS) values also increased. The aim of this study was to investigate this paradox of age using the Narcotrend depth of anesthesia monitor.
BACKGROUND With an ageing global population, it is important to individualise titration of anaesthetics according to age and by measuring their effect on the brain. A recent study reported that during general surgery, the given concentration of volatile anaesthetics, expressed as a fraction of the minimum alveolar concentration (MAC fraction), decreases by around only 3% per age-decade, which is less than the 6% expected from age-adjusted MAC. Paradoxically, despite the excessive dosing, Bispectral index (BIS) values also increased. OBJECTIVE We planned to investigate the paradox of age when using the Narcotrend depth of anaesthesia monitor. DESIGN Secondary analyses of a prospective observational study. SETTING Tertiary hospital in Switzerland, recordings took place during 2016 and 2017. PATIENTS One thousand and seventy-two patients undergoing cardiac surgery entered the study, and 909 with noise-free recordings and isoflurane anaesthesia were included in this analysis. INTERVENTION We calculated mean end-tidal MAC fraction and mean index value of the Narcotrend depth of sedation monitor used in the study during the prebypass period. Statistical associations were modelled using linear regression, local weighted regression (LOESS) and a generalised additive model (GAM). MAIN OUTCOME MEASURES Primary endpoints in this study were the change in end-tidal MAC fraction and mean Narcotrend index values, both measured per age-decade. RESULTS We observed a linear decrease in end-tidal MAC fraction of 3.2% per age-decade [95% confidence interval (CI) -3.97% to -2.38%, P < 0.001], consistent with previous findings. In contrast to the BIS, mean Narcotrend index values decreased with age at 3.0 index points per age-decade (95% CI, -3.55 points to -2.36 points, P < 0.001), a direction of change commensurate with the increasing age-adjusted MAC fraction with patient age. These relationships were consistent regardless of whether age-adjusted MAC was displayed on the anaesthetic machine. CONCLUSIONS We caution that the 'paradox of age' may in part depend on the choice of depth of sedation monitor.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据