4.7 Article

Molecular detection of SARS-CoV-2 from indoor air samples in environmental monitoring needs adequate temporal coverage and infectivity assessment

期刊

ENVIRONMENTAL RESEARCH
卷 198, 期 -, 页码 -

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.envres.2021.111200

关键词

SARS-CoV-2; Indoor air; Low-risk healthcare unit; RT-qPCR; Residual infectivity

资金

  1. IRCCS Burlo Garofolo (Trieste, Italy) [RC 47/20, RC 15/17, RC 03/20]
  2. Italian Ministry of Health (Italy)

向作者/读者索取更多资源

Research on airborne exposure to SARS-CoV-2 in indoor environments, particularly in healthcare settings, is ongoing. Currently, there is no standardized or optimized method for bioaerosol sampling, leading to limitations in representing temporal and spatial variability of the virus in aerosols. Experimental models indicate that environmental samples with higher viral RNA amplification values may not necessarily have infectivity. Standardization of long-term monitoring and infectivity assessment for SARS-CoV-2 in the air is urgently needed.
The relevance of airborne exposure to SARS-CoV-2 in indoor environments is a matter of research and debate, with special importance for healthcare low-risk settings. Experimental approaches to the bioaerosol sampling are neither standardized nor optimized yet, leading in some cases to limited representativity of the temporal and spatial variability of viral presence in aerosols. Airborne viral viability moreover needs to be assessed. A study has been conducted collecting five 24-h PM10 samples in a COVID-19 geriatric ward in late June 2020, and detecting E and RdRp genes by RT-qPCR with a Ct between 36 and 39. The viral RNA detection at Ct = 36 was related to the maximal numerosity of infected patients hosted in the ward. Lacking a direct infectivity assessment for the collected samples an experimental model has been defined, by seeding twelve nasopharyngeal swab extracts from COVID-19 positive patients on Vero E6 cells; only the four extracts with a viral load above E+10 viral copies (approximately Ct<24) have been able to establish a persistent infection in vitro. Therefore, the cytopathic effect, a key feature of residual infectivity, could be considered unlikely for the environmental PM10 samples showing amplification of viral RNA at Ct = 36 or higher. A standardization of airborne SARS-CoV-2 long-term monitoring and of environmental infectivity assessment is urgently needed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据