4.5 Article

Non-Contact High Voltage Measurement in the Online Partial Discharge Monitoring System

期刊

ENERGIES
卷 14, 期 18, 页码 -

出版社

MDPI
DOI: 10.3390/en14185777

关键词

partial discharge (PD); power transformer monitoring; capacitive probe; high voltage measurement; non-contact measurement

资金

  1. Polish National Centre for Research and Development, within the Applied Research Programme [PBS3/A4/12/2015]

向作者/读者索取更多资源

This article presents an innovative non-contact high voltage measurement system using a capacitive probe, which ensures safe and flexible high voltage measurement. The system is discussed in terms of its principles, implementation, and experimental results.
The article presents an innovative system for non-contact high voltage (HV) measurement, which extends the measurement capabilities of a portable partial discharges (PD) monitoring system intended for diagnostics of power transformers. The proposed method and the developed measuring system are based on the use of a capacitive probe, thanks to which the high voltage measurement is safe (galvanic separation from the objects at ahigh potential). It is also flexible because the voltage ratio of this system can be configured in a wide range by changing the probe's position. The proposed solution makes the portable PD monitoring system fully autonomous and independent of the substation systems and devices. The article presents both the concept of the non-contact HV measurement system and its practical implementation. The procedure for determining the voltage ratio and measurement uncertainty, which is at an acceptable level of 1-5% in laboratory conditions, was discussed in detail. In addition, the article discusses the digital filtering and wavelet de-noising methods implemented in the software of the monitoring system, which makes it possible to measure the voltage in the presence of strong electromagnetic disturbances occurring at the substation. Finally, the results of field tests carried out on a 250 MVA power transformer are presented, which confirmed the high accuracy of the HV measurement using a capacitive probe and the advantages of this technique.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据