4.7 Article

A Multitask Deep-Learning System to Classify Diabetic Macular Edema for Different Optical Coherence Tomography Devices: A Multicenter Analysis

期刊

DIABETES CARE
卷 44, 期 9, 页码 2078-2088

出版社

AMER DIABETES ASSOC
DOI: 10.2337/dc20-3064

关键词

-

向作者/读者索取更多资源

A deep learning system was developed for accurate classification of DME using OCT images, achieving high AUROC values. This system showed excellent performance in automated DME classification, demonstrating potential as an effective screening tool for patients with diabetes.
OBJECTIVE Diabetic macular edema (DME) is the primary cause of vision loss among individuals with diabetes mellitus (DM). We developed, validated, and tested a deep learning (DL) system for classifying DME using images from three common commercially available optical coherence tomography (OCT) devices. RESEARCH DESIGN AND METHODS We trained and validated two versions of a multitask convolution neural network (CNN) to classify DME (center-involved DME [CI-DME], non-CI-DME, or absence of DME) using three-dimensional (3D) volume scans and 2D B-scans, respectively. For both 3D and 2D CNNs, we used the residual network (ResNet) as the backbone. For the 3D CNN, we used a 3D version of ResNet-34 with the last fully connected layer removed as the feature extraction module. A total of 73,746 OCT images were used for training and primary validation. External testing was performed using 26,981 images across seven independent data sets from Singapore, Hong Kong, the U.S., China, and Australia. RESULTS In classifying the presence or absence of DME, the DL system achieved area under the receiver operating characteristic curves (AUROCs) of 0.937 (95% CI 0.920-0.954), 0.958 (0.930-0.977), and 0.965 (0.948-0.977) for the primary data set obtained from CIRRUS, SPECTRALIS, and Triton OCTs, respectively, in addition to AUROCs >0.906 for the external data sets. For further classification of the CI-DME and non-CI-DME subgroups, the AUROCs were 0.968 (0.940-0.995), 0.951 (0.898-0.982), and 0.975 (0.947-0.991) for the primary data set and >0.894 for the external data sets. CONCLUSIONS We demonstrated excellent performance with a DL system for the automated classification of DME, highlighting its potential as a promising second-line screening tool for patients with DM, which may potentially create a more effective triaging mechanism to eye clinics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据