4.7 Article

Hemoglobin A1c-Using Epidemiology to Guide Medical Practice: Kelly West Award Lecture 2020

期刊

DIABETES CARE
卷 44, 期 10, 页码 2197-2204

出版社

AMER DIABETES ASSOC
DOI: 10.2337/dci21-0035

关键词

-

向作者/读者索取更多资源

The discovery of HbA(1c) as a measure of average glucose exposure was a significant advancement in diabetes care. It is now widely used for monitoring and diagnosing diabetes due to its convenience, reliability, and standardization. Epidemiologic studies have shown strong links between HbA(1c) and complications, making it a cornerstone in modern diabetes care.
The discovery that HbA(1c) was a valid and reliable measure of average glucose exposure was one of the most important advances in diabetes care. HbA(1c) was rapidly adopted for monitoring glucose control and is now recommended for the diagnosis of diabetes. HbA(1c) has several advantages over glucose. Glucose assessment requires fasting, has poor preanalytic stability, and is not standardized; concentrations are acutely altered by a number of factors; and measurement can vary depending on sample type (e.g., plasma or whole blood) and source (e.g., capillary, venous, interstitial). HbA(1c) does not require fasting, reflects chronic exposure to glucose over the past 2-3 months, and has low within-person variability, and assays are well standardized. One reason HbA(1c) is widely accepted as a prognostic and diagnostic biomarker is that epidemiologic studies have demonstrated robust links between HbA(1c) and complications, with stronger associations than those observed for usual measures of glucose. Clinical trials have also demonstrated that lowering HbA(1c) slows or prevents the development of microvascular disease. As with all laboratory tests, there are some clinical situations in which HbA(1c) is unreliable (e.g., certain hemoglobin variants, alterations in red blood cell turnover). Recent studies demonstrate that fructosamine and glycated albumin may be substituted as measures of hyperglycemia in these settings. Other approaches to monitoring glucose have recently been introduced, including continuous glucose monitoring, although this technology relies on interstitial glucose and epidemiologic evidence supporting its routine use has not yet been established for most clinical settings. In summary, a large body of epidemiologic evidence has convincingly established HbA(1c) as a cornerstone of modern diabetes care.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据