4.7 Article

Two-dimensional temperature in a detonation channel using two-color OH planar laser-induced fluorescence thermometry

期刊

COMBUSTION AND FLAME
卷 228, 期 -, 页码 259-276

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.combustflame.2021.02.002

关键词

Detonation; Laser diagnostics; Temperature measurement; Planar laser-induced fluorescence

向作者/读者索取更多资源

This work demonstrates single-shot, two-dimensional temperature measurements in a premixed linear detonation channel using two-color OH planar laser-induced fluorescence thermometry. The technique was found suitable for detonation environments based on spectral characteristics, and the precision and accuracy of the method were evaluated under different conditions. The ability to distinguish and quantify detonation burning behavior shows promise for future applications in pressure-gain combustion facilities.
This work demonstrates single-shot, two-dimensional temperature measurements in a premixed linear detonation channel using two-color OH planar laser-induced fluorescence thermometry. Detonation environments result in extreme thermodynamic conditions which create challenges in the resulting spectroscopic behavior. However, thermometry based on the ratio of the P-1(9)/Q(1)(14) transitions within the A(2) Sigma(+) <-(2) Pi(1,0) band of OH was determined to be well-suited for detonation environments based on the spectral characteristics over a wide range of conditions. The technique is demonstrated in the post induction region, focusing on the nominal equilibrium state of the Chapman-Jouguet conditions, on mixtures of stoichiometric H-2 and O-2 diluted with either N-2 or Ar. High-speed chemiluminescence imaging at 2 MHz was used to assess the qualitative dynamics of the detonation structure. The measured temperature fields for the Ar dilution case are relatively spatially uniform, with the distributions mean agreeing well with the theoretical calculation of the Chapman-Jouguet temperature, consistent with preliminary work [Grib et al. , AIAA SciTech Forum, (2021). 2021-0421]. Conversely, the temperature fields for a 50% N-2 dilution case are highly irregular, showing a larger dynamic range in temperature as well as pockets of unburned reactants, which emphasized the significance of this measurement by highlighting various reaction scenarios dictated by detonation waves. The irregularity of the N-2 dilution cases is explained in terms of the scale similarity between the channel size and the detonation cell sizes for the N-2 dilution mixtures, leading to weak or failing detonation modes. Overall, the demonstrated thermometry technique produced a precision (1-sigma) of approximately 4% in atmospheric conditions and approximately 7.7% in strong detonation environments. In addition, the accuracy, defined as the percent difference between the mean and CJ temperature, was approximately 1% in the Ar diluted case. The ability to distinguish and quantify detonation burning behavior is promising for employing this approach for application in pressure-gain combustion facilities such as rotating detonation combustors, however care needs to be taken when interpreting the resulting temperature field, particularly near the wave front, due to the precision and validation range of the present line pair. (C) 2021 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据