The audit demonstrated that the CTC service at St Mark's Hospital is safe and of sufficiently high quality to meet the BSGAR/RCR standards, with most outcomes equal to or above the aspirational target. Areas for service and individual reader improvement were identified. The service was consistently rated good or higher by patients.
AIM: To audit the performance of computed tomography colonography (CTC) at St Mark's Hospital against the joint British Society of Gastrointestinal and Abdominal Radiology (BSGAR) and Royal College of Radiologists (RCR) standards. MATERIALS AND METHODS: A retrospective audit of all CTC studies between January 2012 to December 2017 was performed against the BSGAR/RCR standards along with additional data outwith the guidelines. Evidence was obtained from a central database, radiology information systems (RISs), picture archiving and communication systems (PACSs), and electronic patient records (EPRs). RESULTS: Over the 6 years, 13,143 CTCs were performed and 12,996 (99%) were adequate or better. Of the cases 1,867 had a >6 mm polyp or cancer reported (polyp identification rate [PIR] 14%) and the positive predictive value (PPV) was 93% (1,148/1,240). Median radiation dose was 458 mGy$cm, mean additional acquisition rate was 19% (2,505/13,143), subsequent endoscopy rate was 9% (1,222/13,143) and mean interpretation time for a negative study was 34.6 minutes. Nine perforations occurred (perforation rate of 0.068%) and one was symptomatic (symptomatic perforation rate of 0.008%). For suspected cancers, the same-day endoscopy rate was 27% (96/360) and same-day staging rate was 76% (272/360). Post-imaging colorectal cancer rates (PICRC) was 3.06 per 100 cancers detected and 0.23 per 1,000 CTCs. The service was always rated good or higher by patients. CONCLUSION: This audit shows the CTC service at St Mark's Hospital to be safe and of sufficiently high quality to meet the BSGAR/RCR standards with most outcomes equal to or above the aspirational target. Areas for service and individual reader improvement were also identified. Crown Copyright (C) 2021 Published by Elsevier Ltd on behalf of The Royal College of Radiologists. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据