4.5 Article

Bacterial translocation and microgap formation at a novel conical indexed implant abutment system for single crowns

期刊

CLINICAL ORAL INVESTIGATIONS
卷 26, 期 2, 页码 1375-1389

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00784-021-04112-2

关键词

Acuris; Conometric connection; Bacterial leakage; Microgap; Cement gap; Marginal integrity; CAD; CAM crown

资金

  1. Projekt DEAL

向作者/读者索取更多资源

This study examined the microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems, finding no microbial leakage but small punctate microgaps at the apical aspect of the conometric junction and cement gaps at the crown-coping interface within clinically acceptable limits.
Objectives A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. Material and methods A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. Results qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 mu m), while mean cement gaps of 12 to 145 mu m were observed at the crown-coping interface. Conclusions The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据