4.7 Review

Characteristics of indoor air quality in underground metro stations: A critical review

期刊

BUILDING AND ENVIRONMENT
卷 198, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2021.107907

关键词

Underground metro stations; Indoor air quality; Exposure limit; Particulate matter; Volatile organic compounds; Bio-aerosols

向作者/读者索取更多资源

This research paper provides a comprehensive review of different types of air pollutants, their sources, health impacts, characteristics, and management in underground metro stations. Comparing actual pollutant levels with regulatory guidelines, it was found that particulate matter, volatile organic compounds, and bacteria were often above recommended limits. A focus on gaseous and biological pollutants, health risk assessment, and the influence of thermal parameters on IAQ perception in future research is recommended based on existing studies.
This research paper presents a comprehensive review of different types of air pollutants, their concentration levels, sources contributing to air pollution, health impacts of pollutants, characteristics of air pollutants, influencing factors such as thermal characteristics and subway geometry, and Indoor Air Quality (IAQ) management in underground (UG) Metro stations. In the current study, actual levels of air pollutants were compared with guidelines specified by regulatory agencies to assess the risk of high exposure to toxic levels of air pollutants. It was found that exposure to particulate matter (PM), volatile organic compounds (VOCs), and bacteria were critical as levels were 2-10 times higher in UG metro stations than the permissible exposure limits specified by WHO, EPA, and ACGIH. Concentrations of aromatic VOCs were noted to be high in urban areas while concentrations of carbonyl VOCs were high in suburban areas. High bacterial concentrations were attributed to increased passenger traffic and saturation of air cleaning filters in HVAC systems. Several factors such as station design, depth of the tunnel, indoor thermal conditions, density of passengers, frequency of trains, station locality, and outdoor environmental conditions were found to significantly affect the IAQ of subway metro stations. On the basis of existing studies as well as the current review study, it is recommended that future research work could focus on the characterization of different gaseous and biological air pollutants, health risk assessment of exposure to various air pollutants, and field studies on the influence of thermal parameters on IAQ perception in UG metro stations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据