4.3 Article

Comparative Impact of Isolated Ultrafiltration and Hemodialysis on Fluid Distribution: A Bioimpedance Study

期刊

BLOOD PURIFICATION
卷 51, 期 6, 页码 492-502

出版社

KARGER
DOI: 10.1159/000518228

关键词

Bioimpedance; Calculated osmolarity; Effective osmolality; Fluid distribution; Hemodialysis; Isolated ultrafiltration; Osmolal gap

资金

  1. Jichi Medical University Hospital Clinical Research Grant

向作者/读者索取更多资源

The research compared the effects of HD and IUF on body fluid status, finding that HD had a stronger effect in reducing extracellular water compared to IUF, and there were differences in the effects of HD and IUF on effective osmolality and osmolal gap.
Introduction: Isolated ultrafiltration (IUF) is an alternative treatment for diuretic-resistant patients with fluid retention. Although hemodialysis (HD) predominantly decreases extracellular water (ECW), the impact of IUF on fluid distribution compared with HD remains unclear. Methods: We compared the effect of HD (n = 22) and IUF (n = 10) sessions on the body fluid status using a bioimpedance analysis device (InBody S10). Results: The total ultrafiltration volume was similar between HD and IUF (HD 2.5 +/- 0.3 vs. ICF 2.1 +/- 0.3 L/session, p = 0.196). The reduction rate of ECW was significantly higher than that of intracellular water (ICW) after HD (ECW -7.9% +/- 0.8% vs. ICW -3.0% +/- 0.9%, p < 0.001) and IUF (ECW -5.8% +/- 0.9% vs. ICW -3.6% +/- 0.8%, p = 0.048). However, the change in the ratio of ECW to total body water in HD was significantly larger than that in IUF (HD -3.2% +/- 0.3% vs. ICF -1.1% +/- 0.4%, p < 0.001). The reduction rates in serum tonicity (effective osmolality) were higher after HD than after IUF (HD -1.8% +/- 0.5% vs. IUF -0.6% +/- 0.2%, p = 0.052). Among the components of effective osmolality, the reduction rates of serum K+ and glucose levels after HD were significantly higher than those after IUF (serum K+: HD -30.5% +/- 1.6% vs. IUF -0.5% +/- 3.8%, p < 0.001; serum glucose: HD -15.4% +/- 5.0% vs. IUF 0.7% +/- 4.8%, p = 0.026), while the serum Na+ level was slightly and similarly reduced (HD -0.8% +/- 0.4% vs. IUF -0.8% +/- 0.4%, p = 0.500). The reduction in the osmolal gap value (measured osmolality-calculated osmolarity) was significantly greater after HD sessions than after IUF sessions (HD -12.4 +/- 1.4 vs. IUF 2.0 +/- 1.0 mOsm/kg, p = 0.001). Conclusion: The extracellular fluid reduction effect of HD is stronger than that of IUF. The different changes in effective osmolality and osmolal gap after HD and IUF sessions may be related to the different effects of HD and IUF on fluid distribution.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据