4.3 Article

Experimental investigation on thermal-hydraulic characteristics of a tube equipped with modified vortex-generator inserts

期刊

EXPERIMENTAL HEAT TRANSFER
卷 30, 期 1, 页码 11-24

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/08916152.2015.1135201

关键词

heat transfer enhancement; vortex-generator insert; variable longitudinal spacing; experimental study

资金

  1. Islamic Azad University (IAU), Shahrood Branch

向作者/读者索取更多资源

The heat transfer, pressure drop, and overall performance specification of a straight circular tube fitted with vortex-generator inserts are investigated experimentally. To modify the thermal-hydraulic performance, the longitudinal spacing of winglets is varied along the flow direction. The experiments are performed in the turbulent regime (7,470 <= Re <= 18,670). Good agreement is obtained when the results are compared and validated with previous correlations proposed for the plain tube. The results show that the use of vortex-generator inserts inside the tube yields a higher heat transfer coefficient and pressure drop than the plain tube, and these parameters augment with increasing the number of winglets. The effect of variation of longitudinal spacing of winglets along the vortex-generator inserts on the heat transfer coefficient is higher that the pressure drop. It is also detected that the variation of this parameter affects each arrangement of winglets exclusively.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据