4.6 Article

Is off-clamp robot-assisted partial nephrectomy beneficial for renal function? Data from the CLOCK trial

期刊

BJU INTERNATIONAL
卷 129, 期 2, 页码 217-224

出版社

WILEY
DOI: 10.1111/bju.15503

关键词

robotic; partial nephrectomy; on-clamp; off-clamp; renal tumour

向作者/读者索取更多资源

The study compared the functional outcomes of on- vs off-clamp robot-assisted partial nephrectomy within a randomized controlled trial. The results showed no significant differences in functional outcomes for the two approaches in patients with normal baseline function and two kidneys.
Objectives To compare the functional outcomes of on- vs off-clamp robot-assisted partial nephrectomy (RAPN) within a randomized controlled trial (RCT). Materials and Methods The CLOCK study (CLamp vs Off Clamp the Kidney during robotic partial nephrectomy; NCT 02287987) is a multicentre RCT including patients with normal baseline function, two kidneys and masses with RENAL scores <= 10. Pre- and postoperative renal scintigraphy was prescribed. Renal defatting and hilum isolation were required in both study arms; in the on-clamp arm, ischaemia was imposed until the completion of medullary renorraphy, while in the off-clamp condition it was not allowed throughout the procedure. The primary endpoint was 6-month absolute variation in estimated glomerular filtration rate (AV-GFR); secondary endpoints were: 12, 18 and 24-month AV-GFR; 6-month estimated glomerular filtration rate variation >25% rate (RV-GFR >25); and absolute variation in ipsilateral split renal function (AV-SRF). The planned sample size was 102 + 102 cases, after taking account crossover of cases to the alternate study arm; a 1:1 randomization was performed. AV-GFR and AV-SRF were compared using analysis of covariation, and RV-GFR >25 was assessed using multivariable logistic regression. Intention-to-treat (ITT) and per-protocol analyses (PP) were performed. Results A total of 160 and 164 patients were randomly assigned to on- and off-clamp RAPN, respectively; crossover was observed in 14% and 43% of the on- and off-clamp arms, respectively. We were unable to find any statistically significant difference between on- vs off-clamp with regard to the primary endpoint (ITT: 6-month AV-GFR -6.2 vs -5.1 mL/min, mean difference 0.2 mL/min, 95% confidence interval [CI] -3.1 to 3.4 [P = 0.8]; PP: 6-month AV-GFR -6.8 vs -4.2 mL/min, mean difference 1.6 mL/min, 95% CI -2.3 to 5.5 [P = 0.7]) or with regard to the secondary endpoints. The median warm ischaemia time was 14 vs 15 min in the ITT analysis and 14 vs 0 min in the PP analysis. Conclusion In patients with regular baseline function and two kidneys, we found no evidence of differences in functional outcomes for on- vs off-clamp RAPN.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据