4.8 Article

Aptamer-based electrochemical biosensor for rapid detection of SARS-CoV-2: Nanoscale electrode-aptamer-SARS-CoV-2 imaging by photo-induced force microscopy

期刊

BIOSENSORS & BIOELECTRONICS
卷 195, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2021.113595

关键词

SARS-CoV-2; S-protein; Detection; Aptasensor; Photo-induced force microscopy

资金

  1. Natural Sciences and Engineering Research Council of Canada (NSERC)
  2. Canada Research Chairs program (CRC)
  3. Canada Foundation for Innovation (CFI)
  4. NSERC-Alliance Covid-19 program

向作者/读者索取更多资源

Quick and accurate diagnosis of the COVID-19 is crucial in stopping the spread of the virus. The development of an aptamer-based biosensor on a screen-printed carbon electrode platform shows promise in providing rapid and sensitive detection of SARS-CoV-2, offering a potential solution to the current challenges in COVID-19 diagnosis.
Rapid, mass diagnosis of the coronavirus disease 2019 (COVID-19) is critical to stop the ongoing infection spread. The two standard screening methods to confirm the severe acute respiratory syndrome coronavirus 2 (SARS-CoV2) are polymerase chain reaction (PCR), through the RNA of the virus, and serology by detecting antibodies produced as a response to the viral infection. However, given the detection complexity, cost and relatively long analysis times of these techniques, novel technologies are urgently needed. Here, we report an aptamer-based biosensor developed on a screen-printed carbon electrode platform for rapid, sensitive, and user-friendly detection of SARS-CoV-2. The aptasensor relies on an aptamer targeting the receptor-binding domain (RBD) in the spike protein (S-protein) of the SARS-CoV-2. The aptamer immobilization on gold nanoparticles, and the presence of S-protein in the aptamer-target complex, investigated for the first time by photo-induced force microscopy mapping between 770 and 1910 cm (-1) of the electromagnetic spectrum, revealed abundant S-protein homogeneously distributed on the sensing probe. The detection of SARS-CoV-2 S-protein was achieved by electrochemical impedance spectroscopy after 40 min incubation with several analyte concentrations, yielding a limit of detection of 1.30 pM (66 pg/mL). Moreover, the aptasensor was successfully applied for the detection of a SARS-CoV-2 pseudovirus, thus suggesting it is a promising tool for the diagnosis of COVID-19.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据