Corneal elasticity after oxygen enriched high intensity corneal cross linking assessed using atomic force microscopy

期刊

EXPERIMENTAL EYE RESEARCH
卷 153, 期 -, 页码 51-55

出版社

ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
DOI: 10.1016/j.exer.2016.10.008

关键词

Cornea crosslinking; Ultraviolet light; Corneal elasticity; Atomic force microscopy

资金

  1. Hellenic Society of Intraocular Implants and Refractive Surgery

向作者/读者索取更多资源

The purpose of this study was to assess anterior and mid corneal stromal elasticity after high intensity (HI) corneal cross linking (CXL), with and without oxygen (O-2) enrichment, and compare these results to conventional CXL. Experiments were performed on 25 pairs of human cadaver eyes, divided into four different groups. Group 1 included corneas that did not receive treatment and served as controls; Group 2 included corneas that received conventional CXL treatment (Dresden Protocol: corneal epithelial debridement, 30 min of riboflavin pretreatment followed by 30 min of exposure to 3 mW/cm(2) of ultraviolet light); Group 3 included corneas that received HI CXL treatment (corneal epithelial debridement, 30 min of riboflavin pretreatment followed by 3 min of exposure to 30mW/cm(2) of ultraviolet light); and Group 4 included corneas that received the same treatment as Group 3, except that they were enriched with oxygen (4 L per minute pure O-2 gas stream) during ultraviolet irradiation. In each group, corneas were subdivided to assess anterior stromal elasticity and mid stromal elasticity. Corneal stromal elasticity was quantified using Atomic Force Microscopy (AFM) through micro-indentation. Young's modulus for the anterior corneal stroma was 14.5 +/- 6.0 kPa, 80.7 +/- 44.6 kPa, 36.6 +/- 10.5 kPa, and 30.6 +/- 9.2 kPa, for groups 1, 2, 3 and 4 respectively. Young's modulus for the mid corneal stroma was 5.8 +/- 2.0 kPa, 20.7 +/- 4.3 kPa, 12.1 +/- 4.9 kPa, and 11.7 +/- 3.7 kPa, for groups 1, 2, 3 and 4, respectively. In the anterior stromal region, conventional CXL demonstrated a significantly different result from the control, whereas the two HI CXL protocols were not significantly different from the control. There were no statistical differences between the two HI CXL protocols, although only the HI CXL protocol with O-2 enrichment was significantly different from the conventional CXL group. In the mid stromal region, once again only conventional CXL demonstrated a significantly different result from the control. There were no statistical differences between the two HI CXL protocols, and both HI CXL protocols were significantly different from the conventional CXL group. Oxygen enriched HI CXL seems to offer similar changes in corneal elasticity when compared to HI CXL without the presence O-2. Conventional CXL increases corneal stiffness more than HI CXL both with and without O-2 enrichment. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据