4.5 Review

Low-Fidelity Arthroscopic Simulation Training in Trauma and Orthopaedic Surgery: A Systematic Review of Experimental Studies

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.arthro.2021.05.065

关键词

-

向作者/读者索取更多资源

This study identified and appraised evidence on the effectiveness of low-fidelity arthroscopic simulation in novice populations. The results showed that low-fidelity arthroscopic simulators can improve the performance of novice participants in completing basic arthroscopic procedures and may be more cost-effective than high-fidelity simulators.
Purpose: To identify and appraise evidence assessing the effectiveness of low -fidelity arthroscopic simulation in the acquisition of arthroscopic surgical skills in a novice population. Methods: Four databases were electronically searched in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) algorithm. Studies from any year that described the use of orthopaedic, low -fidelity arthroscopic training models in novice populations were included. Questionnaires, case studies, and review studies were excluded. Risk of bias assessment was conducted using the Cochrane Collaboration's Risk of Bias Tool or the Cochrane Risk of Bias in Non-Randomised Studies of Interventions (ROBINS-I) checklist. Results: Sixteen studies were identified. Using the PRISMA algorithm, 6 studies were included with a total of 131 novice participants. Individual studies ranged from 8 to 40 novices and were of Level I to II evidence. Outcome measurements varied between studies (total 16 different outcomes used). Various outcome measures used for assessing arthroscopic surgical skills within all 6 studies demonstrated significant improvement. A cross-study subjective outcome synthesis revealed low -fidelity arthroscopic simulators reduced time to completion outcomes (2 studies, P < .05), increased Arthroscopic Surgical Skill Evaluation Tool scores (2 studies, P < .01), and confirmed face validity (2 studies) and transfer of skills to cadavers (2 studies) or live patients (1 study). Cost data were under-reported in all studies apart from one. Conclusions: Arthroscopic training using low-fidelity simulators likely improves the performance of novice participants in completing basic arthroscopic procedures. These simulators may also be more cost effective and thus more implementable than their high-fidelity counterparts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据