4.7 Article

An experimental investigation on the performance of TEGs with a compact heat exchanger design towards low-grade thermal energy recovery

期刊

APPLIED THERMAL ENGINEERING
卷 194, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2021.117119

关键词

Thermoelectric generator; Compact heat exchanger; Temperature distribution; Modular design; Pressure drop; Low-grade thermal energy

资金

  1. National Natural Science Foundation of China [51906168, 51822403, 12075160]
  2. Department of Science and Technology of Guangdong Province [2019ZT08G315]
  3. Sichuan Science and Technology Program [19ZX0148Z090101001]
  4. Shenzhen Clean Energy Research Institute

向作者/读者索取更多资源

A novel compact heat exchanger design for modular assembly of thermoelectric generator (TEG) system was proposed, increasing the TEG system's performance with high volumetric power density and low power consumption by considering uniform temperature distribution and flow resistance. The design provides a potential solution for large-scale applications of TEG system in harvesting low-grade thermal energy.
Thermoelectric generator (TEG) is a promising technology for low-grade heat recovery, whereas the scalability of TEGs remains challenging. Modular design with an ideal thermal design provides a potential solution for large scale application of TEG system in harvesting low-grade thermal energy. In this paper, a concept of modular design with a compact thermal design was proposed for the cold and hot sides of TEG system. A compact heat exchanger was fabricated by using diffusion welding technique for the TEG system. The inlet and outlet of the heat exchanger are designed with a tapering geometry to achieve a uniform fluid flow and temperature distribution among the flow channels, and the inlets of the hot-side heat exchangers and the outlets of cold-side heat exchangers can be arranged at the same side to realize a counter-flow thermal design. With the design of compact heat exchanger, the modularization assembly of a TEG system can be achieved and the TEG system can be scaled up by alternately arranging hot- and cold-side heat exchangers. To evaluate the TEG performance with current design, a single unit with five TEG modules was tested at various temperature differences. Despite that a thermoelectric conversion efficiency of 1.64% was obtained at a temperature difference of 96.4 degrees C, the unit exhibited a high volumetric power density (86.4 kW/m(3)) and a negligible power consumption (0.64% of the total power output). Furthermore, the measurements were also carried out to evaluate the temperature distribution across the contacting surface of the heat exchanger and the flow resistance between inlet outlet of the heat exchanger. A low temperature variation (<1.76 degrees C) across the heating surface was indicated at the temperature differences from 26.4 to 96.4 degrees C with a relatively low flow resistance (1.00-4.34 kPa) at the flow rates from 0.026 to 0.06 kg/s. The current design of the heat exchanger realizes a relatively uniform temperature distribution and a low flow resistance, leading to a better performance of the developed TEG and making it feasible for the large-scale applications towards low-grade thermal energy recovery.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据