4.7 Article

Comparative study between heat pipe and shell-and-tube thermal energy storage

期刊

APPLIED THERMAL ENGINEERING
卷 192, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2021.116974

关键词

Latent heat thermal energy storage (LHTES); Phase change material (PCM); Heat pipes; Heat exchanger; Experimental analysis

资金

  1. Ministerio de Ciencia, Innovacion y Universidades de Espana (UE) [RTI2018-093849-B-C31 - MCIU/AEI/FEDER]
  2. Agencia Estatal de Investigacion (AEI), of the Ministerio de Ciencia, Innovacion y Universidades [RED2018-102431-T]
  3. Spanish Government [BES-2016-076554]
  4. ICREA under the ICREA Academia programme
  5. Catalan Government [2017 SGR 1537]

向作者/读者索取更多资源

This study experimentally evaluated the implementation of heat pipes in latent heat thermal energy storage systems. The results showed that heat pipe systems have faster heat transfer rates during charging processes compared to shell and tubes systems, but the low conductivity of the storing material cushioned the high heat transfer rates.
This paper experimentally evaluates the implementation of heat pipes in latent heat thermal energy storage systems. The well-known performance of heat pipes as a heat transfer technology makes them great candidates to be used as heat exchangers. However, previous studies compared their efficacy against solid metal rods, where heat pipes clearly succeeded. Therefore, the objective of this study is to experimentally evaluate the advantages of using heat pipes instead of a common shell and tubes system, during charging processes. In particular, five latent heat thermal energy storage systems were tested. One based on the shell and tubes, and the remaining four based on heat pipes. The experiments were conducted at constant heat transfer fluid temperature and flow rate, and the results were analysed from the temperature, heat transfer, and visual point of view. The results show that in heat pipes systems the phase change material melts homogeneously through all the storage container. However, the shell and tubes tank performed the charging process in 25 min while the fastest heat pipe one took 40 min for it. On the other hand, in the shell and tubes configuration melt from the heat transfer fluid inlet towards the outlet. Moreover, systems with more heat pipe surface inside the heat transfer fluid collector provided higher power rates. Comparing the best and the worst heat pipe storage tanks during the first 30 min, the heat transfer rate increased over 40%. But the storing material low conductivity cushioned those high heat transfer rates.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据