4.6 Article

Carbon Footprint of General, Regional, and Combined Anesthesia for Total Knee Replacements

期刊

ANESTHESIOLOGY
卷 135, 期 6, 页码 976-991

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/ALN.0000000000003967

关键词

-

向作者/读者索取更多资源

The study compared the carbon dioxide equivalent emissions of general anesthesia, spinal anesthesia, and combined anesthesia during total knee replacement surgeries. The results showed that all anesthesia approaches had similar carbon footprints, with certain choices affecting the final emissions, such as using low-flow anesthesia/total intravenous anesthesia, reducing single-use plastics, minimizing oxygen flows, and collaborating with engineers to enhance energy efficiency/renewable electricity.
Background: Health care itself contributes to climate change. Anesthesia is a carbon hotspot, yet few data exist to compare anesthetic choices. The authors examined the carbon dioxide equivalent emissions associated with general anesthesia, spinal anesthesia, and combined (general and spinal anesthesia) during a total knee replacement. Methods: A prospective life cycle assessment of 10 patients in each of three groups undergoing knee replacements was conducted in Melbourne, Australia. The authors collected input data for anesthetic items, gases, and drugs, and electricity for patient warming and anesthetic machine. Sevoflurane or propofol was used for general anesthesia. Life cycle assessment software was used to convert inputs to their carbon footprint (in kilogram carbon dioxide equivalent emissions), with modeled international comparisons. Results: Twenty-nine patients were studied. The carbon dioxide equivalent emissions for general anesthesia were an average 14.9 (95% CI, 9.7 to 22.5) kg carbon dioxide equivalent emissions; spinal anesthesia, 16.9 (95% CI, 13.2 to 20.5) kg carbon dioxide equivalent; and for combined anesthesia, 18.5 (95% CI, 12.5 to 27.3) kg carbon dioxide equivalent. Major sources of carbon dioxide equivalent emissions across all approaches were as follows: electricity for the patient air warmer (average at least 2.5 kg carbon dioxide equivalent [20% total]), single-use items, 3.6 (general anesthesia), 3.4 (spinal), and 4.3 (combined) kg carbon dioxide equivalent emissions, respectively (approximately 25% total). For the general anesthesia and combined groups, sevoflurane contributed an average 4.7 kg carbon dioxide equivalent (35% total) and 3.1 kg carbon dioxide equivalent (19%), respectively. For spinal and combined, washing and sterilizing reusable items contributed 4.5 kg carbon dioxide equivalent (29% total) and 4.1 kg carbon dioxide equivalent (24%) emissions, respectively. Oxygen use was important to the spinal anesthetic carbon footprint (2.8 kg carbon dioxide equivalent, 18%). Modeling showed that intercountry carbon dioxide equivalent emission variability was less than intragroup variability (minimum/maximum). Conclusions: All anesthetic approaches had similar carbon footprints (desflurane and nitrous oxide were not used for general anesthesia). Rather than spinal being a default low carbon approach, several choices determine the final carbon footprint: using low-flow anesthesia/total intravenous anesthesia, reducing single-use plastics, reducing oxygen flows, and collaborating with engineers to augment energy efficiency/renewable electricity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据